Background: Permanent pacemaker (PM) requirement is a known complication after transcatheter aortic valve implantation (TAVI). There are, however, no systematic data concerning this complication.

Objective: To determine the incidence and potential predictors of permanent PM requirement after TAVI based on published literature.

Methods: We conducted a MEDLINE search to identify potentially relevant literature dealing with PM requirement after TAVI. Data were collected on paper extraction forms by 2 independent investigators.

Results: There were 32 relevant published studies comprising data of 5,258 patients without an implanted PM before TAVI. An Edwards-Sapiens® prosthesis (ESP) was implanted in 2,887 patients, whereas 2,371 patients received a CoreValve® prosthesis (CVP). The crude incidence of PM implantation after TAVI was 15%. Six hundred and fourteen of 2,371 (25.8%) CVP patients and 189 of the 2,887 (6.5%) ESP patients had to receive a permanent PM (odds ratio [OR] 4.91, 95% confidence interval [CI] 4.12-5.86, P < 0.001). Presence of right bundle branch block (RBBB) before TAVI was a significant predictor for development of complete atrioventricular (AV) block and subsequent PM need (OR 1.358, 95% CI 1.001-1.841, P = 0.02). More than 90% of all AV-block requiring PM implantation occurred immediately or within 7 days after TAVI.

Conclusion: Patients undergoing TAVI with implantation of CVP are at significantly higher risk for development of AV block and subsequent need for permanent PM, particularly if RBBB preexists. Since AV block occurs in >90% within the first week after the procedure, careful monitoring should be performed for at least 7 days after TAVI.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8167.2011.02211.xDOI Listing

Publication Analysis

Top Keywords

permanent pacemaker
8
transcatheter aortic
8
aortic valve
8
valve implantation
8
tavi
8
implantation tavi
8
requirement tavi
8
block subsequent
8
patients
6
implantation
5

Similar Publications

We describe a rare case of serositis complicating permanent pacemaker implantation presenting 4 weeks postinsertion. A high index of suspicion for this potentially fatal complication is warranted to enable prompt diagnosis and treatment. Serositis should be considered in the differential diagnosis of a patient presenting with chest pain, fever or fatigue following recent permanent pacemaker implantation, particularly if there are elevated inflammatory markers.

View Article and Find Full Text PDF

Background: Transcatheter aortic valve replacement (TAVR) has revolutionized the management of aortic stenosis and has become the standard of care across a broad spectrum of patients with aortic stenosis. However, it is still associated with high incidence of conduction abnormalities, particularly new left bundle branch block (LBBB). Management of these patients remains a challenge.

View Article and Find Full Text PDF

Background: Because it is unclear whether implantable cardioverter-defibrillators (ICDs) are equally effective in patients of all ages, we investigated the association of age with long-term clinical outcomes of patients who underwent ICD implantation.

Methods And Results: A total of 416 consecutive patients (mean age: 69 years) from 4 tertiary hospitals who underwent ICD implantation or were upgraded from an existing permanent pacemaker between January 2011 and November 2022 were enrolled and divided into 3 groups based on age: <65 years (n=158), 65-74 years (n=138), and ≥75 years (n=120). We compared the incidence of all-cause death and adverse cardiovascular events, including cardiac death, appropriate ICD therapy, and heart failure hospitalization.

View Article and Find Full Text PDF

Leadless pacemakers (LPs) are emerging options for bradyarrhythmias. However, extraction can be risky if the device is in an unfavorable position. We present a challenging case of a Nanostim LP (NLP) (Abbott Medical Inc.

View Article and Find Full Text PDF

Background: This case report highlights the conduction disorder anomalies associated with dengue infection, particularly bradyarrhythmias due to dysfunction of the sinus node and atrioventricular node, which may require cardiac stimulation such as pacemaker implantation. This case emphasizes the importance of continuous monitoring and the use of additional diagnostic techniques to detect complications in a timely manner.

Case Summary: A 31-year-old male patient was admitted to our institution with symptoms of dyspnoea, orthopnoea, and severe bradycardia.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!