In emission tomography, image reconstruction and therefore also tracer development and diagnosis may benefit from the use of anatomical side information obtained with other imaging modalities in the same subject, as it helps to correct for the partial volume effect. One way to implement this, is to use the anatomical image for defining the a priori distribution in a maximum-a-posteriori (MAP) reconstruction algorithm. In this contribution, we use the PET-SORTEO Monte Carlo simulator to evaluate the quantitative accuracy reached by three different anatomical priors when reconstructing positron emission tomography (PET) brain images, using volumetric magnetic resonance imaging (MRI) to provide the anatomical information. The priors are: 1) a prior especially developed for FDG PET brain imaging, which relies on a segmentation of the MR-image (Baete , 2004); 2) the joint entropy-prior (Nuyts, 2007); 3) a prior that encourages smoothness within a position dependent neighborhood, computed from the MR-image. The latter prior was recently proposed by our group in (Vunckx and Nuyts, 2010), and was based on the prior presented by Bowsher (2004). The two latter priors do not rely on an explicit segmentation, which makes them more generally applicable than a segmentation-based prior. All three priors produced a compromise between noise and bias that was clearly better than that obtained with postsmoothed maximum likelihood expectation maximization (MLEM) or MAP with a relative difference prior. The performance of the joint entropy prior was slightly worse than that of the other two priors. The performance of the segmentation-based prior is quite sensitive to the accuracy of the segmentation. In contrast to the joint entropy-prior, the Bowsher-prior is easily tuned and does not suffer from convergence problems.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/TMI.2011.2173766 | DOI Listing |
Radiol Case Rep
March 2025
Advanced Radiology Services, P.C., Grand Rapids, Michigan.
"Situs inversus with levocardia" refers to the mirror-image lateral orientation of the abdominal organs with a normally oriented, left-sided heart. This anatomical anomaly arises from abnormalities in the biochemical signaling systems mediating embryological development. We present a case of situs inversus with levocardia incidentally discovered in a healthy 24-year-old male during workup following a motor vehicle collision.
View Article and Find Full Text PDFNeurourol Urodyn
January 2025
Department of Urology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
Introduction And Objective: Urodynamic study (UDS) is required to diagnose bladder outlet obstruction (BOO) during evaluation of benign prostatic hyperplasia (BPH) but is seldom performed due to cost and invasiveness. Therefore, anatomic and clinical parameters to predict BOO have been proposed, including the prostate transition zone index (TZI) which is the ratio of prostate transition zone volume (TZV) to whole gland volume (WGV). Historically computed with ellipsoid volume estimation of prostate WGV and TZV from transrectal ultrasound measurements, controversy exists regarding the utility of TZI to predict likelihood of BOO on UDS and clinical outcomes following BPH surgery.
View Article and Find Full Text PDFJ Shoulder Elbow Surg
January 2025
Department of Orthopaedic Surgery, University of Virginia, Charlottesville, VA, USA.
Background: Surgical techniques for biceps tenodesis vary in approach, fixation strategy, and anatomic location without clear superior technique for this common procedure.
Hypothesis/purpose: The purpose of this study was to prospectively evaluate a randomized cohort of patients undergoing arthroscopic suprapectoral (ASBT) with interference screw fixation using an inlay technique versus mini-open subpectoral (MOBT) with a unicortical button implant using an onlay technique with regards to 1) clinical outcome measures and 2) structural healing as evaluated by ultrasound.
Methods: From May 2017 to April 2021, patients undergoing biceps tenodesis were preoperatively randomized to either ASBT or MOBT.
Eur J Orthop Surg Traumatol
January 2025
Department of Orthopaedic Surgery, University of California San Diego, 200 West Arbor Drive MC 8894, San Diego, CA, 92103, USA.
Purpose: While treatment modalities for Maisonneuve fractures involving the proximal third of the fibula are established, no studies to date have reported outcomes associated with syndesmotic-only fixation of middle third fibular shaft fractures. The purpose of this study was to evaluate outcomes associated with syndesmotic-only fixation in the treatment of Maisonneuve fractures involving the middle third of the fibula.
Methods: A retrospective review was conducted on 257 cases of syndesmotic ankle instability with associated fibular fractures at a level 1 trauma center between 2013 and 2023.
Sensors (Basel)
December 2024
School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, China.
Megavoltage computed tomography (MVCT) plays a crucial role in patient positioning and dose reconstruction during tomotherapy. However, due to the limited scan field of view (sFOV), the entire cross-section of certain patients may not be fully covered, resulting in projection data truncation. Truncation artifacts in MVCT can compromise registration accuracy with the planned kilovoltage computed tomography (KVCT) and hinder subsequent MVCT-based adaptive planning.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!