Background: The need for early identification of postural abnormalities without exposing patients to constant radiation has stimulated the development of instruments aiming to measure the spinal curvatures.

Objective: To verify the validity, repeatability and reproducibility of angular measures of sagittal curvatures of the spine obtained using an adapted arcometer, by comparing them with Cobb angles of the respective curvatures obtained by using X-rays.

Methods: 52 participants were submitted to two procedures designed to evaluate the thoracic and lumbar curvatures: (1) X-ray examination from which the Cobb angles (CA) of both curvatures were obtained, and (2) measuring the angles with the arcometer (AA). Two evaluators collected the data using the arcometer, with the rods placed at T1, T12, L1 and L5 spinous processes levels in a way as to permit linear measurements which, with aid of trigonometry, supplied the AA.

Results: There was a very strong and significant correlation between AA and CA (r=0.94; p<0.01), with no-significant difference (p=0.32), for the thoracic curvature. There was a strong and significant correlation for the lumbar curvature (r=0.71; p<0.01) between AA and CA, with no-significant difference (p=0.30). There is a very strong correlation between intra-evaluator and inter-evaluator AA.

Conclusion: It was possible to quantify reliably the thoracic and lumbar curvatures with the arcometer and it can thus be considered valid and reliable and for use in evaluating spinal curvatures in the sagittal plane.

Download full-text PDF

Source
http://dx.doi.org/10.1590/s1413-35552011005000031DOI Listing

Publication Analysis

Top Keywords

repeatability reproducibility
8
thoracic lumbar
8
cobb angles
8
validation repeatability
4
reproducibility noninvasive
4
noninvasive instrument
4
instrument measuring
4
measuring thoracic
4
lumbar curvature
4
curvature spine
4

Similar Publications

Background: Virtual patients (VPs) are computer screen-based simulations of patient-clinician encounters. VP use is limited by cost and low scalability.

Objective: Show proof-of-concept that VPs powered by large language models (LLMs) generate authentic dialogs, accurate representations of patient preferences, and personalized feedback on clinical performance; and explore LLMs for rating dialog and feedback quality.

View Article and Find Full Text PDF

Purpose: Evaluating sacral fractures is crucial in fragility fractures of the pelvis. Dual-energy CT (DECT) is considered useful for diagnosing unclear fractures on single-energy CT (SECT). This study aims to investigate the effectiveness of DECT in diagnosing sacral fractures.

View Article and Find Full Text PDF

To establish a rapid and sensitive detection method for the porcine reproductive and respiratory syndrome virus (PRRSV), gene-specific primers and a TaqMan probe were designed based on the gene of PRRSV, and a new stable fully pre-mixed reverse transcription real-time fluorescence quantitative PCR (RT-qPCR) reaction mixture was developed. A simple and rapid RT-qPCR detection method for PRRSV was developed by optimizing nucleic acid amplification conditions. The results showed that the method was able to specifically detect PRRSV without cross-reactivity with the other 11 porcine susceptible viruses.

View Article and Find Full Text PDF

Pulse oximetry at two sensor placement sites in conscious foals.

Acta Vet Scand

January 2025

Department of Equine and Small Animal Medicine, Faculty of Veterinary Medicine, University of Helsinki, Viikintie 49, 00014, Helsinki, Finland.

Background: Pulse oximetry has not been thoroughly evaluated for assessment of oxygenation in conscious foals. Compared with invasive arterial blood sampling, it is a painless and non-invasive method for real-time monitoring of blood oxygen saturation. The aim of this prospective clinical study was to evaluate the usability, validity, and reliability of pulse oximetry at two measuring sites (lip and caudal abdominal skin fold) for blood oxygen saturation measurement in conscious foals with and without respiratory compromise.

View Article and Find Full Text PDF

Background: The clinical translation of positron emission tomography (PET) radiotracers for cancer management presents complex challenges. We have developed consensus-based recommendations for preclinical and clinical assessment of novel and established radiotracers, applied to image different cancer types, to improve the standardisation of translational methodologies and accelerate clinical implementation.

Methods: A consensus process was developed using the RAND/UCLA Appropriateness Method (RAM) to gather insights from a multidisciplinary panel of 38 key stakeholders on the appropriateness of preclinical and clinical methodologies and stakeholder engagement for PET radiotracer translation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!