Purpose: Conventionally, radiography studies revealed prolonged glenoidal drill hole visibilities with an unclear influence to the clinical outcome after arthroscopic Bankart repair using Poly-Laevo-Lactic-Acid (PLLA) anchors. The primary aim of the present study was the separated assessment of drill hole consolidation (DHC) and the concomitant osseous reaction (OR) of the glenoidal bio-degradation process in new specific magnetic resonance grading systems. In accordance with the specific DHC and the OR graduation, the clinical relevance was the secondary focus.
Methods: Twenty-eight patients with arthroscopic Bankart repair using knotless PLLA anchors were prospectively followed and analyzed using a clinical scoring system (3, 6, 15 and 32 months). The T2-weighted OR and T1-weighted DHC were assessed using specific magnetic resonance imaging grading protocols (15 and 32 months).
Results: Longitudinal assessments revealed successive clinical status improvements over time (32 months: Rowe 95.7 ± 3.8; Walch-Duplay 93.8 ± 6.6; Constant 93.9 ± 4.5; ASES 93.8 ± 6.9; DASH 28.6 ± 7.2; NAS(pain) 1.1 ± 1.3; NAS(function) 1.3 ± 1.4). The initial OR level regressed over the 15-32 month period while the DHC showed significant drill hole reductions (P < 0.05). The inferior glenoid revealed a significantly increased bio-degradation capacity (P < 0.05) with drill hole enlargements in 14.3%. Neither the OR nor the drill hole enlargements influenced the clinical status. In no case were clinical or radiologic signs for a foreign body reaction.
Conclusion: Knotless bio-anchors provide secure glenoidal fixation for Bankart repair without any specific clinical or MR evidence of an inflammatory response. The clinical status remained unaffected by the bio-degradation process.
Level Of Evidence: IV.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00167-011-1721-8 | DOI Listing |
Proc Natl Acad Sci U S A
January 2025
Department of Earth Sciences, University of Oregon, Eugene, OR 97403.
Volcanic provinces are among the most active but least well understood landscapes on Earth. Here, we show that the central Cascade arc, USA, exhibits systematic spatial covariation of topography and hydrology that are linked to aging volcanic bedrock, suggesting systematic controls on landscape evolution. At the Cascade crest, a locus of Quaternary volcanism, water circulates deeply through the upper [Formula: see text]1 km of crust but transitions to shallow and dominantly horizontal flow as rocks age away from the arc front.
View Article and Find Full Text PDFDent Res J (Isfahan)
December 2024
Department of Periodontology, Student Research Committee, Tabriz University of Medical Sciences, Tabriz, Iran.
Background: Chronic apical periodontitis (AP) may influence the outcome of root canal treatment. Thus, it is important to diagnose AP using the best method available. This research was done to compare the diagnostic accuracy of parallel periapical radiography (PR) and different field of views (FOVs) of cone-beam computed tomography (CBCT).
View Article and Find Full Text PDFEur J Trauma Emerg Surg
January 2025
AO Research Institute Davos, Davos, Switzerland.
Background: Digitally Enhanced Hands-on Surgical Training (DEHST) platform was introduced to overcome the lack of training capabilities for the challenging task of freehand distal interlocking of intramedullary nails. It demonstrates high perceived realism for surgeons, and novices perform significantly better after DEHST training. However, characterization of how performance improves remained unexplored.
View Article and Find Full Text PDFMaterials (Basel)
December 2024
College of Mechanical Engineering, Baoji University of Arts and Sciences, Baoji 721016, China.
The surface roughness of hole machining greatly influences the mechanical properties of parts, such as early fatigue failure and corrosion resistance. The boring and trepanning association (BTA) deep hole drilling with axial vibration assistance is a compound machining process of the tool cutting and the guide block extrusion. At the same time, the surface of the hole wall is also ironed by the axial large amplitude and low-frequency vibration of the guide block.
View Article and Find Full Text PDFAnimals (Basel)
December 2024
Department of Veterinary Medicine, Kangwon National University, Chuncheon-si 24341, Gangwon-do, Republic of Korea.
A 3D-printed guide is an effective method for accurately placing pedicle screws in dog vertebrae. While a conventional drill guide allows precise pilot hole formation, it can lead to potential screw wobbling during insertion. In this study, we applied a technique that assists with both drilling and screw insertion, and we compared the accuracy of screw placement using this approach with that achieved by the conventional drill guide.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!