The use of predictive parameters for weaning from mechanical ventilation is a rather polemic topic, and the results of studies on this topic are divergent. Regardless of the use of these predictive parameters, the spontaneous breathing trial (SBT) is recommended. The objective of the present study was to review the utility of predictive parameters for weaning in adults. To that end, we searched the Medline, LILACS, and PubMed databases in order to review articles published between 1991 and 2009, in English or in Portuguese, using the following search terms: weaning/desmame, extubation/extubação, and weaning indexes/indices de desmame. The use of clinical impression is an inexact means of predicting weaning outcomes. The most widely used weaning parameter is the RR/tidal volume (V T) ratio, although this parameter presents heterogeneous results in terms of accuracy. Other relevant parameters are MIP, airway occlusion pressure (P0.1), the P0.1/MIP ratio, RR, V T, minute volume, and the index based on compliance, RR, oxygenation, and MIP. An index created in Brazil, the integrative weaning index, has shown high accuracy. Although recommended, the SBT is inaccurate, approximately 15% of extubation failures going unidentified in SBTs. The main limitations of the weaning indexes are related to their use in specific populations, the cut-off points selected, and variations in the types of measurement. Since the SBT and the clinical impression are not 100% accurate, the weaning parameters can be useful, especially in situations in which the decision as to weaning is difficult.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1590/s1806-37132011000500016 | DOI Listing |
J Cardiothorac Surg
January 2025
Department of Anesthesiology, West China Hospital, Sichuan University, 37 Guo Xue Xiang, Chengdu, 610041, China.
Background: Near-infrared spectroscopy (NIRS) enables a non-invasive measurement of tissue oxygen saturation (StO) in regions illuminated by near-infrared lights. Vascular occlusion test (VOT) serves as a model to artificially induce forearm ischemia-reperfusion. The combination of StO monitoring and VOT allows for dynamic evaluation of the balance between oxygen delivery and consumption in tissue, as well as the functional reserve of microcirculation.
View Article and Find Full Text PDFBMC Med Imaging
January 2025
Department of Ultrasound in Medicine, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, 200233, China.
Background: Benign and malignant breast tumors differ in their microvasculature morphology and distribution. Histologic biomarkers of malignant breast tumors are also correlated with the microvasculature. There is a lack of imaging technology for evaluating the microvasculature.
View Article and Find Full Text PDFBMC Public Health
January 2025
Meizhou Hospital of Guangzhou University of Chinese Medicine, Meizhou, Guangdong, China.
Objective: Hypertension increases the prevalence of depression to a certain extent and identification and diagnosis of depression frequently pose challenges for clinicians. The study aimed to construct and validate a scoring model predicting the prevalence of depression with hypertension.
Methods: 6124 individuals with hypertension were utilized from the 2007 to 2020 National Health and Nutrition Examination Survey database (NHANES), including 645 subjects that were assessed to have depressive symptoms, 390 in the development group and 255 in the validation group.
BMC Med Imaging
January 2025
Department of Neurosurgery, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China.
Purpose: We used knowledge discovery from radiomics of T2-weighted imaging (T2WI) and contrast-enhanced T1-weighted imaging (T1C) for assessing relapse risk in patients with high-grade meningiomas (HGMs).
Methods: 279 features were extracted from each ROI including 9 histogram features, 220 Gy-level co-occurrence matrix features, 20 Gy-level run-length matrix features, 5 auto-regressive model features, 20 wavelets transform features and 5 absolute gradient statistics features. The datasets were randomly divided into two groups, the training set (~ 70%) and the test set (~ 30%).
Korean J Ophthalmol
January 2025
Department of Ophthalmology, Seoul National University Bundang Hospital, Seongnam, Korea.
Purpose: To evaluate the accuracy of toric intraocular lens (IOL) axis prediction between two preoperative measurement devices: the optical biometry (IOLMaster 500 or 700) and the dual Scheimpflug topography (Galilei G4).
Methods: Medical records of 64 eyes from 44 patients who underwent phacoemulsification and posterior chamber toric IOL (Zeiss AT TORBI 709M) implantation between July 2017 and January 2022 were reviewed. All patients underwent preoperative evaluation by optical biometry (IOLMaster 500 or IOLMaster 700) and Galilei G4.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!