Passive markers for tracking surgical instruments in real-time 3-D ultrasound imaging.

IEEE Trans Med Imaging

Ultrasound Division, Siemens Healthcare, Mountain View, CA 94043, USA.

Published: March 2012

A family of passive echogenic markers is presented by which the position and orientation of a surgical instrument can be determined in a 3-D ultrasound volume, using simple image processing. Markers are attached near the distal end of the instrument so that they appear in the ultrasound volume along with the instrument tip. They are detected and measured within the ultrasound image, thus requiring no external tracking device. This approach facilitates imaging instruments and tissue simultaneously in ultrasound-guided interventions. Marker-based estimates of instrument pose can be used in augmented reality displays or for image-based servoing. Design principles for marker shapes are presented that ensure imaging system and measurement uniqueness constraints are met. An error analysis is included that can be used to guide marker design and which also establishes a lower bound on measurement uncertainty. Finally, examples of marker measurement and tracking algorithms are presented along with experimental validation of the concepts.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3638948PMC
http://dx.doi.org/10.1109/TMI.2011.2173586DOI Listing

Publication Analysis

Top Keywords

3-d ultrasound
8
ultrasound volume
8
passive markers
4
markers tracking
4
tracking surgical
4
surgical instruments
4
instruments real-time
4
real-time 3-d
4
ultrasound
4
ultrasound imaging
4

Similar Publications

A Multi-Scale Computational Model of the Hepatic Circulation Applied to Predict the Portal Pressure After Transjugular Intrahepatic Portosystemic Shunt (TIPS).

Int J Numer Method Biomed Eng

January 2025

Hebei Provincial Key Laboratory of Portal Hypertension and Cirrhosis, Xingtai People's Hospital, Xingtai, China; Department of Radiology, Zhongda Hospital, Medical School, Southeast University, Nanjing, China.

Transjugular intrahepatic portosystemic shunt (TIPS) is a widely used surgery for portal hypertension. In clinical practice, the diameter of the stent forming a shunt is usually selected empirically, which will influence the postoperative portal pressure. Clinical studies found that inappropriate portal pressure after TIPS is responsible for poor prognosis; however, there is no scheme to predict postoperative portal pressure.

View Article and Find Full Text PDF

The Lepidopteran pest Trichoplusia ni and the parasitoid wasp Trichogramma brassicae represent a fascinating biological system, important for sustainable agricultural practices but challenging to observe. We present a nondestructive method based on micro-CT scanning technology (CT: computed tomography) for visualizing the internal parts of caterpillar embryos and of emerging parasitoids from infected eggs. Traditional methods of microscopic observation of the opaque egg contents require staining or dissection.

View Article and Find Full Text PDF

We sought to examine how resistance training (RT) status in young healthy individuals, either well resistance trained (T, n=10) or untrained (UT, n=11), affected molecular markers with leg immobilization followed by recovery RT. All participants underwent two weeks of left leg immobilization via a locking leg brace. Afterwards, all participants underwent eight weeks (3 d/week) of knee extensor focused progressive RT.

View Article and Find Full Text PDF

Evaluation of Pedicle Screw Position on Computerized Tomography Using Three-Dimensional Reconstruction Software.

Medicina (Kaunas)

December 2024

Spine Center and Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam 13620, Republic of Korea.

: Recent advances in intraoperative navigation systems have improved the accuracy of pedicle screw placement in spine surgery. However, many hospitals have limited access to these advanced technologies due to resource constraints. In such settings, postoperative computed tomography (CT) evaluation remains crucial for assessing screw placement and related potential complications.

View Article and Find Full Text PDF
Article Synopsis
  • Developed a 3-D acoustic radiation force impulse (ARFI) system for prostate imaging to identify cancerous regions and guide biopsies in one visit using a transrectal probe and 3-D visualization software.
  • The system was tested in a clinical trial comparing ARFI-guided targeted transperineal biopsies with other standard biopsy methods.
  • Results showed ARFI was less effective for lower-grade cancers but performed well for higher-grade cancers, suggesting it could enhance biopsy accuracy when combined with 2-D imaging techniques.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!