Purpose: To determine the biocompatibility of a new wireless intraocular pressure (IOP) transducer (WIT) in rabbit eyes and to correlate its measurements with other pressure-measuring devices.
Methods: The WIT is a ring-shaped intraocular device that allows wireless IOP measurements through radiofrequency. It was implanted into six eyes of New Zealand White rabbits after extracapsular lens extraction. A sham rabbit eye with no transducer implanted was used as a control. The animals were observed and examined by microscopy at various intervals up to 25 months after surgery. IOP was measured at various intervals by pneumotonometry, tonometry, WIT, and manometry. The data from the various devices were compared and analyzed for reproducibility. Two eyes were enucleated at 5.5 and 20 months after implantation and analyzed by histology.
Results: The WIT appears to be well tolerated in the rabbit eye, with no evidence of significant inflammation or scar formation by microscopic in vivo examination. Histology did not reveal intraocular inflammation or membrane formation. Repeated IOP measurements with pneumotonometry, tonometry, and the WIT resulted in SDs of 2.70 mm Hg, 3.35 mm Hg, and 0.81 mm Hg, respectively. The concordance between the WIT and direct manometry measurements was high. A downward drift in IOP measured by the WIT was noted in three rabbits, necessitating recalibration.
Conclusions: The WIT is well tolerated by the rabbit eye. Its measurements are reproducible and in close concordance with manometry. A downward IOP drift warrants further investigation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1167/iovs.11-7878 | DOI Listing |
Invest Ophthalmol Vis Sci
January 2025
Harry S. Truman Memorial Veterans' Hospital, Columbia, Missouri, United States.
Purpose: Sulfur mustard gas (SM) exposure to eyes causes multiple corneal injuries including stromal cell loss in vivo. However, mechanisms mediating stromal cell loss/death remains elusive. This study sought to test the novel hypothesis that SM-induced toxicity to human corneal stromal fibroblasts involves ferroptosis mechanism via p38 MAPK signaling.
View Article and Find Full Text PDFTransl Vis Sci Technol
January 2025
Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.
Purpose: The purpose of this study was to characterize whether pulsed ultrasound (PUS) affects transscleral drug delivery.
Methods: Fluorescein sodium (NaF, 376 Da) and fluorescein isothiocyanate-conjugated dextran 40 (FD-40, 40 kDa) were used as model drugs. Human sclera grafts were placed in modified Franz diffusion cells and were treated by PUS (1 megahertz [MHz], 0.
Mol Pharm
January 2025
School of Pharmacy, University of Eastern Finland, Yliopistonranta 1 C, 70210 Kuopio, Finland.
Glaucoma is a vision-threatening disease that is currently treated with intraocular-pressure-reducing eyedrops that are instilled once or multiple times daily. Unfortunately, the treatment is associated with low patient adherence and suboptimal treatment outcomes. We developed carbonic anhydrase II inhibitors (CAI-II) for a prolonged reduction of intraocular pressure (IOP).
View Article and Find Full Text PDFBMC Ophthalmol
January 2025
Fudan University Eye Ear Nose and Throat Hospital, Shanghai, China.
Background: To evaluate the biosafety, reduction in anterior capsule opacification, and fluctuation in intraocular pressure (IOP) of a new phakic refractive lens (PRL) with a sinusoidal drainage groove design.
Methods: This self-controlled experiment was performed on eight eyes of four rabbits. Each rabbit was implanted with a sinusoidal PRL (PRL-S5) in the right eye and a conventional posterior chamber PRL (PC-PRL) in the left eye.
Pharmaceutics
November 2024
Guangdong Provincial Key Laboratory of Advanced Drug Delivery, Guangdong Provincial Engineering Center of Topical Precise Drug Delivery System, Guangdong Pharmaceutical University, No. 280 University Town Outer Ring East Road, Guangzhou 510006, China.
Background: Internal ocular diseases, such as macular edema, uveitis, and diabetic macular edema require precise delivery of therapeutic agents to specific regions within the eye. However, the eye's complex anatomical structure and physiological barriers present significant challenges to drug penetration and distribution. Traditional eye drops suffer from low bioavailability primarily due to rapid clearance mechanisms.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!