A CMOS image sensor to recognize the cardiovascular disease markers troponin I and C-reactive protein.

Anal Bioanal Chem

College of Bionanotechnology, Kyungwon University, Sujeong-Gu, Seongnam-Si, Gyeonggi-Do, Korea.

Published: January 2012

A complementary metal oxide semiconductor (CMOS) image sensor was utilized to detect the interaction of cardiovascular disease markers, troponin I and C-reactive protein. Each marker with its respective antibodies was adsorbed to an indium nanoparticle (InNP)-coated glass substrate. Dielectric layers of antigens and antibodies bound onto and interacted on conducting InNPs. Normal room light passed through these protein-layer-bound substrates and hit the CMOS image sensor surface, and the number of photons was detected and converted into digital form. We tested this approach for real-time monitoring of cardiac disease markers based on photon count, demonstrating its low cost and its capacity to detect antigens with high sensitivity at picogram per milliliter concentration.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-011-5478-1DOI Listing

Publication Analysis

Top Keywords

cmos image
12
image sensor
12
disease markers
12
cardiovascular disease
8
markers troponin
8
troponin c-reactive
8
c-reactive protein
8
sensor recognize
4
recognize cardiovascular
4
protein complementary
4

Similar Publications

Extreme ultraviolet (EUV) lithography is a cutting-edge technology in contemporary semiconductor chip manufacturing. Monitoring the EUV beam profiles is critical to ensuring consistent quality and precision in the manufacturing process. This study uncovers the practical use of fluorescent nanodiamonds (FNDs) coated on optical image sensors for profiling EUV and soft X-ray (SXR) radiation beams.

View Article and Find Full Text PDF

All-Optically Controlled Memristive Device Based on CuO/TiO Heterostructure Toward Neuromorphic Visual System.

Research (Wash D C)

January 2025

Key Laboratory for UV Light-Emitting Materials and Technology (Ministry of Education), College of Physics, Northeast Normal University, Changchun, China.

The optoelectronic memristor integrates the multifunctionalities of image sensing, storage, and processing, which has been considered as the leading candidate to construct novel neuromorphic visual system. In particular, memristive materials with all-optical modulation and complementary metal oxide semiconductor (CMOS) compatibility are highly desired for energy-efficient image perception. As a p-type oxide material, CuO exhibits outstanding theoretical photoelectric conversion efficiency and broadband photoresponse.

View Article and Find Full Text PDF

Purpose: Minibeam radiotherapy (MBRT) uses small parallel beams of radiation to create a highly modulated dose pattern. The aim of this study is to develop an optical radioluminescence imaging (RLI) approach to perform real-time dose measurement for MBRT.

Methods: MBRT was delivered using an image-guided small animal irradiator equipped with a custom collimator.

View Article and Find Full Text PDF

Epithelial tissues in vitro undergo dynamic changes while differentiating heterogeneously on the culture substrate. This gives rise to diverse cellular arrangements which are undistinguished by conventional analysis approaches, such as transepithelial electrical resistance measurement or permeability assays. In this context, solid substrate-based systems with integrated electrodes and electrochemical impedance monitoring capability can address the limited spatiotemporal resolution of traditional porous membrane-based methods.

View Article and Find Full Text PDF

In this study, we describe a low-noise complementary metal-oxide semiconductor (CMOS) image sensor (CIS) with a 10/11-bit hybrid single-slope analog-to-digital converter (SS-ADC). The proposed hybrid SS-ADC provides a resolution of 11 bits in low-light and 10 bits in high-light. To this end, in the low-light section, the digital-correlated double sampling method using a double data rate structure was used to obtain a noise performance similar to that of the 11-bit SS-ADC under low-light conditions, while maintaining linear in-out characteristics.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!