Thrombolytic therapy for patients with acute myocardial infarction (AMI) has produced the need for an accurate early diagnostic marker. We previously developed and assessed an assay for the creatine kinase (CK)-MB subforms; assay time is 25 minutes. Plasma MB2 (tissue subform) activity, MB1 (plasma-modified subform) activity, and MB2/MB1 ratio in 56 healthy individuals were 0.61 +/- 0.33 units/l, 0.63 +/- 0.33 units/l, and 0.94 +/- 0.39, respectively. Only one individual had both an MB2 activity greater than 1.0 units/l and an MB2/MB1 ratio of more than 1.5. Similar results were obtained in 50 hospitalized patients without cardiac disease; two of these patients had both an MB2 activity and an MB2/MB1 ratio greater than the cutoff values. Among 49 patients with AMI, MB2 activity and the MB2/MB1 ratio began to increase 2 hours after AMI; the ratio reached a plateau of 3.1 by 4-6 hours. The first available plasma sample was abnormal by the subform assay in 67% of patients and by a conventional MB assay in 27% of patients. Assay sensitivities in samples collected at 2-4, 4-6, and 6-8 hours after AMI were 59%, 92%, and 100% for the subform assay and 23%, 50%, and 71% for the conventional assay (p less than 0.03 versus subform assay at each time interval). False-negative results were obtained by the subform and conventional assays in 15 and 45 samples at a mean of 2.3 and 5.8 hours, respectively. Subform assay provides rapid and reliable diagnosis of AMI within 4-6 hours after the onset of symptoms, which is 6 hours before conventional CK-MB assays are accurate.

Download full-text PDF

Source
http://dx.doi.org/10.1161/01.cir.82.3.759DOI Listing

Publication Analysis

Top Keywords

mb2/mb1 ratio
16
subform assay
16
activity mb2/mb1
12
mb2 activity
12
assay
10
acute myocardial
8
myocardial infarction
8
assay time
8
subform activity
8
+/- 033
8

Similar Publications

This study aimed to describe the morphometric relationship of root canal orifices on the pulp floor in the presence/absence of mesiobuccal second canal (MB2) in the maxillary first molars and other aspects of its internal anatomy. Sixty-two maxillary first molars were scanned by micro-CT. The presence of the MB2 canal was verified.

View Article and Find Full Text PDF

We conducted a prospective, controlled study to investigate the use of CK-MB concentration and newer methods such as troponin-T concentration and CK isoforms, in the assessment of myocardial damage caused by radiofrequency current or low energy DC catheter ablation. The study population consisted of 3 consecutive patients who underwent low energy catheter ablation, 28 consecutive patients subjected to radiofrequency ablation, and 4 patients who were subjected to radiofrequency energy ablation but also had external DC shocks for cardioversion of atrial fibrillation that occurred during the procedure. The control group comprised eight subjects undergoing electrophysiological study.

View Article and Find Full Text PDF

The automated (CK)MB1,2/MM1,2,3 isoform measurement, based on electrophoresis, has been simplified to the point that it has become possible to perform this analysis on a 24-h routine basis. We studied analytical aspects of this analysis and its clinical relevance in relation to other biochemical markers (CK total, CKMB activity, CKMB mass, myoglobin, Troponin I and Troponin T) in patients with acute myocardial infarction (AMI), patients with unstable angina pectoris (UAP), and healthy donors. Furthermore, the additional significance of the analysis was evaluated in patients with clinically unexpected, raised CKMB/CK total activities.

View Article and Find Full Text PDF

The presence of myocardial injury during non-surgical coronary revascularization has been evaluated by means of highly specific and sensitive biochemical markers. Troponin T, creatine kinase-MB isoenzyme mass concentration, and creatine kinase MB2/MB1 isoform ratio have been determined in 80 patients who underwent coronary revascularization with percutaneous transluminal coronary angioplasty (PTCA). Forty-five patients underwent balloon angioplasty, 15 rotational atherectomy, 10 directional atherectomy, and 10 elective coronary stenting.

View Article and Find Full Text PDF

Background: Although there remains particular concern about late malignant ventricular arrhythmias arising from myocardial damage induced by catheter ablation, the extent of myocardial injury resulting from clinical ablation procedures has not been fully studied. We conducted a prospective, controlled study to investigate the use of two newer markers of myocardial integrity, troponin-T concentration and creatine kinase isoforms, and a traditional marker, creatine kinase-MB concentration, in the assessment of myocardial injury following radiofrequency catheter ablation.

Methods And Results: The study population consisted of 28 consecutive patients subjected to radiofrequency catheter ablation, and the control group comprised eight subjects undergoing diagnostic electrophysiology study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!