Three models of different stent designs implanted in a cerebral aneurysm, originating from the Virtual Intracranial Stenting Challenge '07, are meshed and the flow characteristics simulated using commercial computational fluid dynamics (CFD) software in order to investigate the effects of non-Newtonian viscosity and pulsatile flow. Conventional mass inflow and wall shear stress (WSS) output are used as a means of comparing the CFD simulations. In addition, a WSS distribution is presented, which clearly discriminates in favour of the stent design identified by other groups. It is concluded that non-Newtonian and pulsatile effects are important to include in order to avoid underestimating wss, to understand dynamic flow effects, and to discriminate more effectively between stent designs.

Download full-text PDF

Source
http://dx.doi.org/10.1177/09544119JEIM894DOI Listing

Publication Analysis

Top Keywords

stent designs
8
non-newtonian flow
4
flow pulsatility
4
effects
4
pulsatility effects
4
effects simulation
4
simulation models
4
models stented
4
stented intracranial
4
intracranial aneurysm
4

Similar Publications

Purpose: To report on in-vivo intrarenal pressure (IRP) during flexible ureteroscopy for treatment of kidney stones while using the novel flexible and navigable suction ureteral access sheath (FANS).

Methods: A retrospective observational analysis was performed for 25 patients undergoing routine flexible ureteroscopy for treatment of renal stones between February 2024 and June 2024 from two centres in Canada. The LithoVue Elite™ ureteroscope (Boston Scientific Corp.

View Article and Find Full Text PDF

Background: The septum is often underdeveloped in East Asian populations, and traditional endogenous extension stents may not adequately fulfill the requirements for rhinoplasty. Herein, we present an innovative exogenous extension framework featuring a mortise and tenon structure specifically designed for East Asians.

Methods: This framework comprises a mushroom-shaped rib cartilage component and a lancet-shaped expanded polytetrafluoroethylene (ePTFE) element, which are interconnected through a mortise and tenon design.

View Article and Find Full Text PDF

Background: Stroke requires timely intervention, with carotid endarterectomy (CEA) and carotid artery stenting (CAS) increasingly used in select acute carotid-related stroke patients. We aimed to build a model to predict neurologic functional independence (modified Rankin scale, mRS ≤ 2) in this high-risk group.

Study Design: We analyzed data from 302 stroke patients undergoing urgent CEA or CAS between 2015 and 2023 at a tertiary Comprehensive Stroke Center.

View Article and Find Full Text PDF

Background: First-generation bioresorbable scaffolds (BRS) increased risks of stent thrombosis and adverse events. The Bioheart scaffold is a new poly-L-lactic acid-based BRS.

Objectives: This study sought to evaluate the efficacy and safety of the BRS in patients with coronary artery disease.

View Article and Find Full Text PDF

Background: The risk-benefit ratio of the Absorb bioresorbable vascular scaffold (BVS) may vary before and after 3 years, the time point of complete bioresorption of the poly-L-lactic acid scaffold.

Objectives: The aim of this study was to determine the time-varying outcomes of the Absorb BVS compared with cobalt-chromium everolimus-eluting stents (EES) from a large individual-patient-data pooled analysis of randomized trials.

Methods: The individual patient data from 5 trials that randomized 5,988 patients undergoing percutaneous coronary intervention to the Absorb BVS vs EES with 5-year follow-up were pooled.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!