Medical imaging plays a central role in a vast range of healthcare practices. The usefulness of 3D visualizations has been demonstrated for many types of treatment planning. Nevertheless, full access to 3D renderings outside of the radiology department is still scarce even for many image-centric specialties. Our work stems from the hypothesis that this under-utilization is partly due to existing visualization systems not taking the prerequisites of this application domain fully into account. We have developed a medical visualization table intended to better fit the clinical reality. The overall design goals were two-fold: similarity to a real physical situation and a very low learning threshold. This paper describes the development of the visualization table with focus on key design decisions. The developed features include two novel interaction components for touch tables. A user study including five orthopedic surgeons demonstrates that the system is appropriate and useful for this application domain.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TVCG.2011.224DOI Listing

Publication Analysis

Top Keywords

medical visualization
8
application domain
8
visualization table
8
multi-touch table
4
table system
4
system medical
4
visualization
4
visualization application
4
application orthopedic
4
orthopedic surgery
4

Similar Publications

Economic impact of initial glaucoma treatment with selective laser trabeculoplasty on the Brazilian Public Health System.

Arq Bras Oftalmol

January 2025

Discipline of Health Management and Economics, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brazil.

Purpose: To evaluate the economic impact of the following initial treatment scenarios for glaucoma on the Brazilian Public Health System (SUS): (1) traditional continuous instillation of hypotensive eye drops and (2) single session of selective laser trabeculoplasty.

Methods: Economic impact was analyzed in three scenarios, from the least to the most conservative, for a hypothetical cohort of 5,000 individuals with open-angle glaucoma. Thereafter, projections were made on the basis of a glaucoma prevalence of 3% in the 2021 Brazilian population size.

View Article and Find Full Text PDF

Retinopathy of prematurity: Accuracy of ROPScore and WINROP algorithms in a Brazilian population.

Arq Bras Oftalmol

January 2025

Department of Ophthalmology and Visual Sciences, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brazil.

Purpose: To assess the sensitivity and specificity of the retinopathy of prematurity score (ROPScore) and weight, insulin-like growth factor-1, retinopathy of prematurity algorithm in predicting the risk of developing severe retinopathy of prematurity (prethreshold type 1) in a sample of preterm infants in Brazil.

Methods: Retrospective analysis of medical records of preterm infants (n=288) with birth weight of ≤1500 g and/or gestational age of 23-32 weeks in a neonatal unit in Southern Brazil from May 2013 to December 2020 (92 months).

Results: The incidence of confirmed severe retinopathy of prematurity was 6.

View Article and Find Full Text PDF

Short-term orthokeratology effects on corneal biomechanics with a focus on SPA1 and stress-strain index (SSI) parameters in pediatric myopia.

Arq Bras Oftalmol

January 2025

Department of Ophthalmology, Guangdong Eye Institute, Guangdong General Hospital, Guangdong Academy of Medical Sciences. No. 106 Zhongshan Er Road, Guangzhou 510080, China.

Purpose: Although the orthokeratology effects on corneal biomechanics have been proven with clinical trials, reports of stiffness parameter change are scarce. This study investigated the short-term orthokeratology effects in pediatric myopia and compared stiffness parameter changes to those published in recent clinical investigations. This prospective study aimed to investigate corneal biomechanics changes induced by short-term overnight orthokeratology treatment, focusing on stiffness parameter at A1 and stress-strain index.

View Article and Find Full Text PDF

Protocol for visualizing the chromatin assembly properties of epigenetic protein complexes via an HTM module-mediated artificial tethering system.

STAR Protoc

January 2025

School of Life Sciences, Lanzhou University, Lanzhou 730000, Gansu, P.R. China; Key Laboratory of Cell Activities and Stress Adaptations, Ministry of Education, Lanzhou University, Lanzhou 730000, Gansu, P.R. China. Electronic address:

The detailed chromatin assembly processes for many epigenetic regulatory complexes are largely unknown. Here, we present a protocol utilizing heterochromatin-targeting module (HTM) module-mediated chromatin tethering followed by microscopy-based visualization to detect the recruitment priority between two components in Polycomb repressive complex 1 (PRC1). Moreover, we detail procedures for detecting the resultant histone-modifying activities of PRC1 using immunofluorescence (IF) analyses.

View Article and Find Full Text PDF

Purpose: To evaluate intermediate-term outcomes and complications associated with Ahmed glaucoma valve (AGV) implantation in eyes with type 1 keratoprosthesis (KPro).

Methods: We retrospectively reviewed records of 43 eyes of 43 Indian patients with type 1 KPro and AGV from 2009 to 2021 with a minimum of 6-months of follow-up. Five eyes that had AGV before KPro were excluded, leaving 38 eyes for analysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!