Purpose: To evaluate the risk of eye injuries by determining intraocular pressure during high speed projectile impacts.

Methods: A pneumatic cannon was used to impact eyes with a variety of projectiles at multiple velocities. Intraocular pressure was measured with a small pressure sensor inserted through the optic nerve. A total of 36 tests were performed on 12 porcine eyes with a range of velocities between 6.2 m/s and 66.5 m/s. Projectiles selected for the test series included a 6.35  mm diameter metal ball, a 9.25  mm diameter aluminum rod, and an 11.16  mm diameter aluminum rod. Experiments were designed with velocities in the range of projectile consumer products such as toy guns.

Results: A range of intraocular pressures ranged between 2017 mmHg to 26,426 mmHg (39 psi-511 psi). Four of the 36 impacts resulted in globe rupture.

Conclusions: Intraocular pressures dramatically above normal physiological pressure were observed for high speed projectile impacts. These pressure data provide critical insight to chronic ocular injuries and long-term complications such as glaucoma and cataracts.

Download full-text PDF

Source
http://dx.doi.org/10.3109/02713683.2011.601841DOI Listing

Publication Analysis

Top Keywords

intraocular pressure
12
high speed
12
speed projectile
12
risk eye
8
eye injuries
8
pressure high
8
projectile impacts
8
diameter aluminum
8
aluminum rod
8
intraocular pressures
8

Similar Publications

Attachment of Hydrogel Patches to Eye Tissue through Gel Transfer using Flexible Foils.

ACS Appl Mater Interfaces

January 2025

Department of Microsystems Engineering (IMTEK), Laboratory for Chemistry & Physics of Interfaces (CPI), Albert Ludwigs Universität Freiburg, Georges Köhler Allee 103, 79110 Freiburg, Germany.

Glaucoma, a leading cause of blindness, demands innovative and effective treatments that surpass the limitations of current drug and surgical interventions to lower intraocular pressure. This study describes the generation of cell-repellent hydrogel patches, their deposition on the ocular surface, and a photoinduced chemical binding between the patches and the collagens of the eye. The hydrophilic and protein-repellent hydrogel patch is composed of a copolymer made from dimethylacrylamide and a comonomer unit with anthraquinone moieties.

View Article and Find Full Text PDF

We present a case of Acute Angle-Closure Crisis (AACC) precipitated by primary transient psychogenic polydipsia; we believe that our case is the first of its kind to be reported. A 74-year-old male presented to the emergency department with altered mental status due to acute-onset hyponatremia. Six days after admission, the patient noticed painful loss of vision in his right eye and an ipsilateral headache lasting 10-15 minutes.

View Article and Find Full Text PDF

Prcis: Cognitive impairment in multiple domains was observed in primary open angle glaucoma patients as compared to age and gender matched healthy controls.

Objective: Evaluation of cognitive impairment in individuals with Primary Open Angle Glaucoma (POAG).

Methods: In this case-control study, individuals with POAG (cases, n=70) were compared with age- and sex-matched healthy individuals (controls, n=70) using detailed ophthalmological evaluation, cognitive assessment and serum cortisol level.

View Article and Find Full Text PDF

Prcis: In the real-world, retrospective, EXPAND study of consecutive adults with glaucoma, ab-externo gel stent implantation effectively lowered intraocular pressure (34%) and the medication burden (61%), with transient/self-resolving hypotony as the most frequent adverse event (28%).

Purpose: To assess effectiveness and safety of ab-externo gel stent (GS) implantation in glaucoma.

Methods: Multicenter, real-world, retrospective study.

View Article and Find Full Text PDF

Background: This study presents the one-year outcomes of a modified technique for transscleral suture fixation of a posterior chamber intraocular lens (PCIOL) in aphakic eyes.

Methods: A retrospective chart review was conducted on 45 patients who underwent transscleral suture fixation of a foldable one-piece PCIOL through scleral pockets. Preoperative data and follow-up data for a minimum of 12 months were collected for all patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!