Purpose: To investigate the impact of typical scan score (TSS) on discriminating glaucomatous and healthy eyes by scanning laser polarimetry and spectral domain optical coherence tomography (SD-OCT) in 32 peripapillary sectors.

Patients And Methods: One hundred two glaucoma patients and 32 healthy controls underwent standard automated perimetry, 24-hour intraocular pressure profile, optic disc photography, GDxVCC, and SD-OCT measurements. For controls, only very typical scans (TSS=100) were accepted. Glaucoma patients were divided into 3 subgroups (very typical: TSS=100; typical: 99≥TSS≥80, atypical: TSS<80). Receiver operating characteristic curves were constructed for mean retinal nerve fiber layer values, sector data, and nerve fiber indicator (NFI). Sensitivity was estimated at ≥90% specificity to compare the discriminating ability of each imaging modality.

Results: For discrimination between healthy and glaucomatous eyes with very typical scans, the NFI and inferior sector analyses 26 to 27 demonstrated the highest sensitivity at ≥90% specificity in GDxVCC and SD-OCT, respectively. For the typical and atypical groups, sensitivity at ≥90% specificity decreased for all 32 peripapillary sectors on an average by 10.9% and 17.9% for GDxVCC and by 4.9% and 0.8% for SD-OCT. For GDxVCC, diagnostic performance of peripapillary sectors decreased with lower TSS, especially in temporosuperior and inferotemporal sectors (sensitivity at ≥90% specificity decreased by 55.3% and by 37.8% in the atypical group).

Conclusions: Diagnostic accuracy is comparable for SD-OCT and GDxVCC if typical scans (TSS=100) are investigated. Decreasing TSS is associated with a decrease in diagnostic accuracy for discriminating healthy and glaucomatous eyes by scanning laser polarimetry. NFI is less influenced than the global or sector retinal nerve fiber layer thickness. The TSS score should be included in the standard printout. Diagnostic accuracy of SD-OCT is barely influenced by low TSS.

Download full-text PDF

Source
http://dx.doi.org/10.1097/IJG.0b013e318237c8c5DOI Listing

Publication Analysis

Top Keywords

glaucoma patients
8
glaucoma diagnostic
4
diagnostic performance
4
performance gdxvcc
4
gdxvcc spectralis
4
spectralis oct
4
oct eyes
4
eyes atypical
4
atypical retardation
4
retardation pattern
4

Similar Publications

Background: Bacterial contamination of medical equipment is a significant risk in both human and veterinary medicine, leading to potential cross-contamination between clinicians, technicians, patients, and healthcare professionals. Pathogens can persist on surfaces, resulting in healthcare-associated infections. Tonometry used to measure intraocular pressure for diagnosing conditions like glaucoma and uveitis, is crucial in both human and veterinary care.

View Article and Find Full Text PDF

Artificial intelligence and glaucoma: a lucid and comprehensive review.

Front Med (Lausanne)

December 2024

Department of Eye Function Laboratory, Eye Hospital, China Academy of Chinese Medical Sciences, Beijing, China.

Glaucoma is a pathologically irreversible eye illness in the realm of ophthalmic diseases. Because it is difficult to detect concealed and non-obvious progressive changes, clinical diagnosis and treatment of glaucoma is extremely challenging. At the same time, screening and monitoring for glaucoma disease progression are crucial.

View Article and Find Full Text PDF

Human Herpesvirus 6A Infection-Associated Acute Anterior Uveitis.

J Inflamm Res

December 2024

Department of Ophthalmology, the First Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou, Zhejiang Province, 310003, People's Republic of China.

Human herpesvirus 6 (HHV-6) infection can cause ophthalmic diseases in immunocompetent patients, recipients of bone marrow transplants, and patients with acquired immunodeficiency syndrome (AIDS). This study describes the case of a healthy 37-year-old male who presented with unilateral anterior uveitis (AU), significant anterior chamber exudation, pupillary membrane closure, increased intraocular pressure, and eyelid edema. Notably, HHV-6A was the only pathogenic agent identified in the blood and aqueous humor.

View Article and Find Full Text PDF

Preserflo MicroShunt (PMS) implantation is a minimally invasive surgical procedure for treating glaucoma. Postoperative hypotony, a common complication of PMS implantation, can be prevented and treated with 10-0 nylon insertion. In this report, we present a case of postoperative hypotony following PMS implantation that was treated with intraluminal insertion of 9-0 nylon.

View Article and Find Full Text PDF

Objective: This study aims to determine the outcomes of probing and external dacryocystorhinostomy (exDCR) for congenital nasolacrimal duct obstruction (cNLDO) and the factors influencing the success rates in pediatric cNLDO.

Design: A retrospective sample collection was conducted at the oculoplastic referral center over 10 years (January 2012 to December 2022) for cNLDO patients who had undergone probing or exDCR.

Methodology: Data were retrospectively reviewed for patients aged ≤18 years who underwent probing or exDCR.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!