Cardiac computed tomography represents an important advancement in the ability to assess coronary vessels. The accuracy of these non-invasive imaging studies is limited, however, by the presence of calcium, since calcium blooming artifacts lead to an over-estimation of the degree of luminal narrowing. To address this problem, we have developed a unified decomposition-based iterative reconstruction formulation, where different penalty functions are imposed on dense objects (i.e. calcium) and soft tissue. The result is a quantifiable reduction in blooming artifacts without the introduction of new distortions away from the blooming observed in other methods. Results are shown for simulations, phantoms, ex vivo, and in vivo studies.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/56/22/008DOI Listing

Publication Analysis

Top Keywords

blooming artifacts
12
reconstruction formulation
8
decomposition-based reconstruction
4
formulation reducing
4
blooming
4
reducing blooming
4
artifacts cardiac
4
cardiac computed
4
computed tomography
4
tomography represents
4

Similar Publications

Diffuse-type giant cell tumor of the tendon sheath (GCTTS) is a rare, benign, yet locally aggressive soft tissue tumor commonly affecting the hand. This case report presents a 55-year-old male with a 5-year history of GCTTS in the flexor tendon sheath of the long finger. MRI played a critical role in both diagnosis and surgical planning, revealing key features such as the tumor's 10 cm length, hemosiderin deposition, and blooming artifacts.

View Article and Find Full Text PDF

This study aims to improve our understanding of acute ischemic stroke clot imaging by integrating CT attenuation information with MRI susceptibility signal of thrombi. For this proof-of-principle experimental study, fifty-seven clot analogs were produced using ovine venous blood with a broad histological spectrum. Each clot analog was analyzed to determine its RBC content and chemical composition, including water, Fe III, sodium, pH, and pO2.

View Article and Find Full Text PDF

A rare case of intratumoral hemorrhage in a young adult with adamantinomatous craniopharyngioma.

Radiol Case Rep

January 2025

Department of Pathological Anatomy, Faculty of Medicine, University of Padjadjaran, Dr. Hasan Sadikin General Hospital, Jl. Pasteur No. 38, Pasteur, Sukajadi, Bandung City, West Java 40161, Indonesia.

Craniopharyngiomas are rare, slow growing tumors arising along the craniopharyngeal duct. The incidence of craniopharyngioma was 0.13 per 100,000 persons per year.

View Article and Find Full Text PDF

Objectives: To assess the metal artifact reductions of dual-energy computed tomography (DECT) high-energy virtual monochromatic images (VMI) combined with the single energy metal artifact reduction (SEMER) (CANON MEDICAL SYSTEMS, Otawara, Japan) processing techniques for iodine (I)-125 seed identification in postimplant computed tomography (CT) after prostate brachytherapy.

Methods: Dual-energy acquisition with fast tube voltage switching was performed on a prostate phantom with simulated seeds and six clinical cases treated with I-125 prostate brachytherapy. The images were retrospectively reconstructed at VMI energy levels of 65-200 keV and with and without SEMAR (SEMAR and non-SEMAR images).

View Article and Find Full Text PDF

Novel Bioreactor Design for Non-invasive Longitudinal Monitoring of Tissue-Engineered Heart Valves in 7T MRI and Ultrasound.

Ann Biomed Eng

October 2024

Department of Biohybrid & Medical Textile (BioTex), Center for Biohybrid Medical Systems (CBMS), Institute for Applied Medical Engineering, RWTH Aachen University, Forckenbeckstr. 55, 52074, Aachen, Germany.

The development of cardiovascular implants is abundant, yet their clinical adoption remains a significant challenge in the treatment of valvular diseases. Tissue-engineered heart valves (TEHV) have emerged as a promising solution due to their remodeling capabilities, which have been extensively studied in recent years. However, ensuring reproducible production and clinical translation of TEHV requires robust longitudinal monitoring methods.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!