Backscatter factors, B, and mass energy-absorption coefficient ratios, (μ(en)/ρ)(w, air), for the determination of the surface dose in diagnostic radiology were calculated using Monte Carlo simulations. The main purpose was to extend the range of available data to qualities used in modern x-ray techniques, particularly for interventional radiology. A comprehensive database for mono-energetic photons between 4 and 150 keV and different field sizes was created for a 15 cm thick water phantom. Backscattered spectra were calculated with the PENELOPE Monte Carlo system, scoring track-length fluence differential in energy with negligible statistical uncertainty; using the Monte Carlo computed spectra, B factors and (μ(en)/ρ)(w, air) were then calculated numerically for each energy. Weighted averaging procedures were subsequently used to convolve incident clinical spectra with mono-energetic data. The method was benchmarked against full Monte Carlo calculations of incident clinical spectra obtaining differences within 0.3-0.6%. The technique used enables the calculation of B and (μ(en)/ρ)(w, air) for any incident spectrum without further time-consuming Monte Carlo simulations. The adequacy of the extended dosimetry data to a broader range of clinical qualities than those currently available, while keeping consistency with existing data, was confirmed through detailed comparisons. Mono-energetic and spectra-averaged values were compared with published data, including those in ICRU Report 74 and IAEA TRS-457, finding average differences of 0.6%. Results are provided in comprehensive tables appropriated for clinical use. Additional qualities can easily be calculated using a designed GUI interface in conjunction with software to generate incident photon spectra.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/0031-9155/56/22/012 | DOI Listing |
Eur J Clin Pharmacol
December 2024
Center for Pharmacometrics, Institute of Interdisciplinary Integrative Medicine Research, Shanghai University of Traditional Chinese Medicine, No.1200 Cailun Road, Shanghai, 201203, China.
Objectives: This study aimed to quantitatively evaluate the efficacy and safety of first-line systemic therapies for treating advanced hepatocellular carcinoma (aHCC).
Methods: The study included clinical trials of first-line systemic therapies for aHCC since the approval of sorafenib in 2007. Hazard function models were used to describe changes in overall survival (OS) and progression-free survival (PFS) over time.
ACS Appl Mater Interfaces
December 2024
TCS Research, Sahyadri Park 2, Rajiv Gandhi Infotech Park, Hinjewadi Phase 3, Pune 411057, India.
Realization of a sustainable hydrogen economy in the future requires the development of efficient and cost-effective catalysts for its production at scale. MXenes (MX) are a class of 2D materials with 'n' layers of carbon or nitrogen (X) interleaved by 'n+1' layers of transition metal (M) and have emerged as promising materials for various applications including catalysts for hydrogen evolution reaction (HER). Their properties are intimately related to both their composition and their atomic structure.
View Article and Find Full Text PDFBMC Public Health
December 2024
Independent Researcher, Ho Chi Minh, 727300, Vietnam.
Background: The mental health of Chinese international student returnees is a critical concern impacting their well-being and successful reintegration into home society, especially in the post-COVID-19 era. This study examines how beliefs about changing living conditions, emigration intentions, and belief in fate influence depression levels among these returnees.
Methods: A cross-sectional survey collected data from 1,014 returnees through WeChat public groups.
Sci Rep
December 2024
Khost Mechanics Institute, Khost, Afghanistan.
Control charts are commonly used for process monitoring under the assumption that the variable of interest follows a normal distribution. However, this assumption is frequently violated in real-world applications. In this study, we develop an adaptive control chart based on the exponentially weighted moving average (EWMA) statistic to monitor irregular variations in the mean of the Truncated Transmuted Burr-II (TTB-II) distribution, employing Hastings approximation for normalization.
View Article and Find Full Text PDFEur J Nucl Med Mol Imaging
December 2024
Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 18, Bern, 3010, Switzerland.
Purpose: Long axial field-of-view (LAFOV) positron emission tomography/computed tomography (PET/CT) scanners enable high sensitivity and wide anatomical coverage. Therefore, they seem ideal to perform post-selective internal radiation therapy (SIRT) Y scans, which are needed, to confirm that the dose is delivered to the tumors and that healthy organs are spared. However, it is unclear to what extent the use of LAFOV PET is feasible and which dosimetry approaches results in accurate measurements.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!