Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: The purpose of our study was to compare high-resolution gadofosveset-enhanced MR angiography (MRA) with the reference standard CT angiography (CTA) in planning endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms.
Subjects And Methods: Thirty consecutive patients were included in this prospective study. CTA was performed routinely before EVAR for stent-graft implantation planning and selection. In addition, first-pass and, after a delay of 10 minutes, steady-state MRA were performed using the blood pool contrast agent gadofosveset for study purposes. Standard diameter and length parameters for stent-graft evaluation rendered from CTA and MRA were compared. According to the results of MRA measurements, stent-grafts were selected for each patient and compared with the device actually implanted. Image quality was assessed using subjective image quality parameters.
Results: Diameter and length measurements showed small but significant differences (p < 0.001) between MRA and CTA. Stent-graft selection according to these measurements showed 100% concordance between both modalities. Subjective imaging parameters showed significantly better results for CTA compared with MRA (p < 0.001).
Conclusion: In this study, MRA using a blood pool contrast agent has shown the ability to provide reliable and exact measurements before EVAR, allowing noninvasive planning of the intervention despite lower image-quality and without the disadvantages of ionizing radiation and nephrotoxicity.