Purpose: To measure accuracy and speed for detection of vascular progression in retinopathy of prematurity (ROP) from serial images. Two strategies are compared: static side-by-side presentation and dynamic flickering of superimposed image pairs.

Design: Prospective comparative study.

Methods: Fifteen de-identified, wide-angle retinal image pairs were taken from infants who eventually developed plus disease. Image pairs representing vascular disease progression were taken ≥1 week apart, and control images without progression were taken on the same day. Dynamic flickering pairs were created by digital image registration. Ten experts independently reviewed each image pair on a secure website using both strategies, and were asked to identify progression or state that images were identical. Accuracy and speed were measured, using examination date and ophthalmoscopic findings as a reference standard.

Results: Using static images, experts were accurate in a mean (%) ± standard deviation (SD) of 11.4 of 15 (76%) ± 1.7 image pairs. Using dynamic flickering images, experts were accurate in a mean (%) ± SD of 11.3 of 15 (75%) ± 1.7 image pairs. There was no significant difference in accuracy between these strategies (P = .420). Diagnostic speed was faster using dynamic flickering (24.7 ± 8.3 seconds) vs static side-by-side images (40.3 ± 18.3 seconds) (P = .002). Experts reported higher confidence when interpreting dynamic flickering images (P = .001).

Conclusions: Retinal imaging provides objective documentation of vascular appearance, with potentially improved ability to recognize ROP progression compared to standard ophthalmoscopy. Speed of identifying vascular progression was faster by review of dynamic flickering image pairs than by static side-by-side images, although there was no difference in accuracy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3266465PMC
http://dx.doi.org/10.1016/j.ajo.2011.08.030DOI Listing

Publication Analysis

Top Keywords

dynamic flickering
24
image pairs
20
static side-by-side
12
images
9
vascular disease
8
disease progression
8
progression retinopathy
8
retinopathy prematurity
8
accuracy speed
8
vascular progression
8

Similar Publications

Purpose: Changes in choroidal thickness (ChT) are proposed to predict myopia development but evidence is mixed. We investigated time courses of choroidal responses, following different types of dynamic artificial stimulation in chicks with and without spectacle lenses, as well as changes in retinal dopamine metabolism and expression of candidate genes.

Methods: Chicks were kept in an arena surrounded by computer monitors presenting dynamic checkerboard fields of small, medium and large size.

View Article and Find Full Text PDF

Retinal microvascular dysfunction in systemic sclerosis.

Microvasc Res

December 2024

Department of Cardiology, University Heart Center, University Hospital and University of Zurich, Zurich, Switzerland; Center for Translational and Experimental Cardiology (CTEC), Department of Cardiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland. Electronic address:

Background And Aims: Systemic sclerosis (SSc) is a systemic autoimmune disease, characterized by widespread microvasculopathy and fibrosis. Vascular and endothelial cell changes appear to precede other features of SSc. Retinal vascular analysis is a new, easy-to-use tool for the assessment of retinal microvascular function.

View Article and Find Full Text PDF

Self-oscillation, a control approach inspired by biological systems, demonstrates an autonomous, continuous, and regular response to constant external environmental stimuli. Until now, most self-oscillation systems have relied on a static external environment that continuously supplies energy, while materials typically absorb ambient energy only intermittently. In this article, we propose an innovative self-oscillation of liquid crystal elastomer (LCE) fiber-slide system driven by a self-flickering light source, which can efficiently regulate the energy input in sync with the self-oscillating behavior under constant voltage.

View Article and Find Full Text PDF

Salient emotional visual cues receive prioritized processing in human visual cortex. To what extent emotional facilitation relies on preattentional stimulus processing preceding semantic analysis remains controversial. Making use of steady-state visual evoke potentials frequency-tagged to meaningful complex emotional scenes and their scrambled versions, presented in a 4-Hz rapid serial visual presentation fashion, the current study tested temporal dynamics of semantic and emotional cue processing.

View Article and Find Full Text PDF

Introduction: Top-down mechanisms that regulate attentional control are influenced by task demands and individuals' goals, while bottom-up processes are influenced by salient stimuli. Analogous networks are involved in both processes (e.g.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!