A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Volar plating for unstable proximal interphalangeal joint dorsal fracture-dislocations. | LitMetric

Volar plating for unstable proximal interphalangeal joint dorsal fracture-dislocations.

J Hand Surg Am

Department of Hand & Reconstructive Microsurgery, National University Hospital, National University Health System, Singapore.

Published: January 2012

Purpose: To report our results of open reduction internal fixation with volar mini plate and screw fixation for unstable dorsal fracture dislocations (DFDs) of the proximal interphalangeal (PIP) joint.

Methods: We performed a retrospective review of 13 consecutive DFDs of the PIP joint treated with volar mini plate and screw fixation, measuring both clinical and radiological outcomes.

Results: The age range of our patients was 15 to 56 years (average, 33 y). Six injuries were related to work, 5 to sports, and 2 to motor vehicle accidents. Of the 13 DFDs, 6 were comminuted. Articular involvement ranged from 30% to 70% (average, 44%). The average time to surgery was 7 days (range, 0-23 d). Patients had follow-up of 12 to 60 months (average, 25 mo). Four patients had a postoperative course complicated by plate and screw removal at an average of 4 months later, either as part of a secondary procedure to improve range of motion or owing to patient request. All patients returned to their original occupation. Of the 13 patients, 11 were satisfied with the result, and 12 of 13 had either no or mild pain. All 13 DFDs united in good alignment but 3 showed degenerative changes. Average grip strength was 85% of the unaffected side, and average active PIP joint and distal interphalangeal joint motion arcs were 75° and 65°, respectively. Average Quick Disabilities of Arm, Shoulder, and Hand score was 4 (range, 0-9). All patients had non-tender swelling of the proximal interphalangeal joints but no signs of flexor tenosynovitis or infection.

Conclusions: Fixation of unstable PIP joint DFDs via a volar approach is technically feasible with mini plates and screws. This treatment allows early active range of motion and provides good objective and subjective outcomes; however, noteworthy complications occurred in 39% of patients.

Type Of Study/level Of Evidence: Therapeutic IV.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhsa.2011.08.030DOI Listing

Publication Analysis

Top Keywords

proximal interphalangeal
12
plate screw
12
pip joint
12
interphalangeal joint
8
volar mini
8
mini plate
8
screw fixation
8
fixation unstable
8
average
8
range motion
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!