Fringe inverse videogrammetry based on global pose estimation is presented to measure a three-dimensional (3D) coordinate. The main components involve an LCD screen, a tactile probe equipped with a microcamera, and a portable personal computer. The LCD is utilized to display fringes, a microcamera is installed on the tactile probe, and the 3D coordinate of the center of the probe tip can be calculated through the microcamera's pose. Fourier fringe analysis is exploited to complete subpixel location of reference points. A convex-relaxation optimization algorithm is employed to estimate the global camera pose, which guarantees global convergence compared with bundle adjustment, a local pose estimation algorithm. The experiments demonstrate that fringe inverse videogrammetry can measure the 3D coordinate precisely.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/AO.50.005630 | DOI Listing |
JCI Insight
December 2024
Departments of Pediatrics and Emergency Medicine, Emory University School of Medicine and Children's Healthcare of Atlanta, Atlanta, Georgia, USA.
To reduce debt burden and encourage the pursuit of research-focused careers, most MD-PhD programs provide medical school tuition remission and an annual stipend. However, prolonged training compared with MD physicians postpones the time until MD-PhD physicians earn a full salary. We compared lifetime earning potential for MD-PhD physicians in academia with their MD colleagues in the same clinical specialty.
View Article and Find Full Text PDFState-of-the-art computational methods combined with common idealized structural models provide an incomplete understanding of experimental observations on real nanostructures, since manufacturing introduces unavoidable deviations from the design. We propose to close this knowledge gap by using the real structure of a manufactured nanostructure as input in computations to obtain a realistic comparison with measurements on the same nanostructure. We demonstrate this approach on the structure of a real inverse woodpile photonic bandgap crystal made from silicon, as previously obtained by synchrotron X-ray imaging.
View Article and Find Full Text PDFAberration-corrected gratings are widely applied in spectral analysis owing to their dispersion and convergence properties. However, the phase distribution error of the exposure interference field reduces the accuracy of the groove density distribution, making it difficult to satisfy the needs of high-precision spectral instruments. Therefore, this paper establishes an error model for the phase distribution of the spherical wave exposure interference field, describing the relationship between the phase distribution error and the recording parameter error.
View Article and Find Full Text PDFSpeckle-based X-ray imaging (SBI) is a phase-contrast method developed at and for highly coherent X-ray sources, such as synchrotrons, to increase the contrast of weakly absorbing objects. Consequently, it complements the conventional attenuation-based X-ray imaging. Meanwhile, attempts to establish SBI at less coherent laboratory sources have been performed, ranging from liquid metal-jet X-ray sources to microfocus X-ray tubes.
View Article and Find Full Text PDFIntroduction: Nurses working in the emergency department experience high rates of burnout. The purpose of this study was to determine job-related factors affecting the well-being of emergency nurses.
Methods: In this cross-sectional study data were collected through multiple methods.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!