Objective: Saphenous vein, in situ right gastroepiploic artery, and right internal thoracic artery grafts are routinely used to revascularize the right coronary artery. Little is known about the predictive value of objective preoperative angiographic parameters on midterm graft patency.

Methods: We prospectively enrolled 210 consecutive patients undergoing coronary revascularization. Revascularization of the right coronary artery was randomly performed with the saphenous vein grafts in 81 patients and the right gastroepiploic artery in 92 patients. During the same study period, 37 patients received right coronary artery revascularization with the right internal thoracic artery used in a Y-composite fashion. All patients underwent a protocol-driven coronary angiogram 3 years after surgery. Preoperative angiographic parameters included minimum lumen diameter percent stenosis measured by quantitative angiography. A graft was considered "not functional" with patency scores of 0 to 2 and "functional" with patency scores of 3 or 4.

Results: Angiographic follow-up was 100% complete. A significant difference in the distribution of flow patterns was observed in the 3 groups. In multivariate analysis, the use of a saphenous vein graft was associated with superior graft functionality compared with the other conduits (odds ratio, 6.1; 95% confidence interval, 2.4-15). Graft function was negatively influenced by the minimum lumen diameter (odds ratio, 0.11; confidence interval, 0.05-0.25). In the right gastroepiploic artery and right internal thoracic artery groups, the proportion of functional grafts was higher when the minimum lumen diameter was below a threshold value in the third minimum lumen diameter quartile (0.64-1.30 mm).

Conclusions: Preoperative angiography predicts graft patency in the right gastroepiploic artery and right internal thoracic artery, whereas the flow pattern in saphenous vein grafts is significantly less influenced by quantitative angiographic parameters.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jtcvs.2011.07.017DOI Listing

Publication Analysis

Top Keywords

gastroepiploic artery
20
saphenous vein
20
internal thoracic
20
thoracic artery
20
coronary artery
16
minimum lumen
16
lumen diameter
16
artery
14
artery internal
12
angiographic parameters
12

Similar Publications

Aneurysmal rupture in microscopic polyangiitis: a case-based review.

Clin Rheumatol

January 2025

Department of Medical Laboratory Science, Faculty of Health Sciences, Hokkaido University, Sapporo, Hokkaido, Japan.

Microscopic polyangiitis (MPA) affects small and medium vessel, which sometimes leads to arterial aneurysms. In English database, only 15 reports refer to ruptured aneurysms in MPA. We experienced a fatal case with MPA who developed multiple visceral aneurysms, resulting in rupture of the hepatic aneurysm.

View Article and Find Full Text PDF

BACKGROUND Recipient hepatic arteries are generally used for arterial reconstructions in living donor liver transplantation. When the hepatic arteries are not feasible, the right gastroepiploic artery is one of the options for arterial reconstructions. In this study, we evaluate the feasibility of using the right gastroepiploic artery and report the analyzed retrospective patient outcomes.

View Article and Find Full Text PDF

Simultaneous gastroepiploic artery to right coronary artery bypass and trans-catheter aortic valve implantation: case series.

Gen Thorac Cardiovasc Surg Cases

January 2025

Department of Thoracic and Cardiovascular Surgery, Wakayama Medical University, 811-1 Kimiidera, Wakayama City, Wakayama, 641-8509, Japan.

Patients with coronary artery disease undergoing trans-catheter aortic valve implantation (TAVI) often receive TAVI alone. However, in cases of severe coronary lesions or anticipated difficulty in coronary access post-TAVI, percutaneous coronary intervention or coronary artery bypass grafting may be necessary. We performed simultaneous gastroepiploic artery to posterior descending artery bypass and TAVI in two patients with severe calcification of the right coronary artery ostium which is unsuitable for percutaneous intervention.

View Article and Find Full Text PDF

Gastric Stenosis Four Years After Adjustable Gastric Band Removal Surgery-A Video Case Report.

Obes Surg

December 2024

Division of Gastroenterology, Department of Internal Medicine, Ilsan Paik Hospital, Inje University College of Medicine, Goyang, Republic of Korea.

Laparoscopic adjustable gastric banding (LAGB) is a type of bariatric surgery. Gastric stenosis or obstruction is a known complication of LAGB; however, its occurrence after band removal is extremely rare. A 60-year-old female, who had undergone LAGB 6 years earlier and band removal 4 years prior, presented to the hospital with recurrent vomiting.

View Article and Find Full Text PDF
Article Synopsis
  • The study evaluated the clinical outcomes of using the right gastroepiploic artery in minimally invasive coronary artery bypass grafting procedures.
  • A total of 428 patients were analyzed, with the right gastroepiploic artery used in 18.2% of cases, leading to a high rate of successful revascularization (93.6% total, 98.7% complete).
  • Postoperative results revealed no in-hospital deaths, a low incidence of new atrial fibrillation (9%), and a manageable median ICU stay of 2 days, indicating favorable outcomes with this surgical approach.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!