High resolution diffusion tensor imaging (DTI) can provide important information on brain development, yet it is challenging in live neonatal rats due to the small size of neonatal brain and motion-sensitive nature of DTI. Imaging in live neonatal rats has clear advantages over fixed brain scans, as longitudinal and functional studies would be feasible to understand neuro-developmental abnormalities. In this study, we developed imaging strategies that can be used to obtain high resolution 3D DTI images in live neonatal rats at postnatal day 5 (PND5) and PND14, using only 3 h of imaging acquisition time. An optimized 3D DTI pulse sequence and appropriate animal setup to minimize physiological motion artifacts are the keys to successful high resolution 3D DTI imaging. Thus, a 3D rapid acquisition relaxation enhancement DTI sequence with twin navigator echoes was implemented to accelerate imaging acquisition time and minimize motion artifacts. It has been suggested that neonatal mammals possess a unique ability to tolerate mild-to-moderate hypothermia and hypoxia without long term impact. Thus, we additionally utilized this ability to minimize motion artifacts in magnetic resonance images by carefully suppressing the respiratory rate to around 15/min for PND5 and 30/min for PND14 using mild-to-moderate hypothermia. These imaging strategies have been successfully implemented to study how the effect of cocaine exposure in dams might affect brain development in their rat pups. Image quality resulting from this in vivo DTI study was comparable to ex vivo scans. fractional anisotropy values were also similar between the live and fixed brain scans. The capability of acquiring high quality in vivo DTI imaging offers a valuable opportunity to study many neurological disorders in brain development in an authentic living environment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3189600PMC
http://dx.doi.org/10.3389/fpsyt.2011.00054DOI Listing

Publication Analysis

Top Keywords

high resolution
16
live neonatal
16
neonatal rats
16
brain development
12
dti imaging
12
motion artifacts
12
imaging
9
resolution diffusion
8
diffusion tensor
8
tensor imaging
8

Similar Publications

Background: The clinical manifestations and course of rheumatoid arthritis-associated interstitial lung disease (RA-ILD) exhibits considerable heterogeneity. In this study, we aimed to explore radiographic progression over a defined period, employing the Warrick score as a semi-quantitative measure in early RA-ILD, and to assess the associated risk factors for progression.

Methods: RA-ILD patients underwent consecutive Warrick scoring based on initial high-resolution computed tomography (HRCT) at diagnosis and the first follow-up.

View Article and Find Full Text PDF

Background And Purpose: To evaluate various anatomical parameters and their relationship to chorda tympani nerve (CTN) injury and round window (RW) access during cochlear implantation.

Materials And Methods: Ultra-high-resolution CT images of 66 patients were retrospectively reviewed and compared with operative reports. The facial recess and the round window were analyzed, mainly using the chorda-facial angle (CFA), the width of the facial recess, the CTN-tympanic annulus distance, the RW-mastoid portion of the facial nerve angle, and the type of RW.

View Article and Find Full Text PDF

Polysomnography (PSG) is crucial for diagnosing sleep disorders, but manual scoring of PSG is time-consuming and subjective, leading to high variability. While machine-learning models have improved PSG scoring, their clinical use is hindered by the 'black-box' nature. In this study, we present SleepXViT, an automatic sleep staging system using Vision Transformer (ViT) that provides intuitive, consistent explanations by mimicking human 'visual scoring'.

View Article and Find Full Text PDF

Functional magnetic resonance imaging (fMRI) has dramatically advanced non-invasive human brain mapping and decoding. Functional near-infrared spectroscopy (fNIRS) and high-density diffuse optical tomography (HD-DOT) non-invasively measure blood oxygen fluctuations related to brain activity, like fMRI, at the brain surface, using more-lightweight equipment that circumvents ergonomic and logistical limitations of fMRI. HD-DOT grids have smaller inter-optode spacing (~ 13 mm) than sparse fNIRS (~ 30 mm) and therefore provide higher image quality, with spatial resolution ~ 1/2 that of fMRI, when using the several source-detector distances (13-40 mm) afforded by the HD-DOT grid.

View Article and Find Full Text PDF

High-resolution fluorescence imaging of ultracold atoms and molecules is paramount to performing quantum simulation and computation in optical lattices and tweezers. Imaging durations in these experiments typically range from a millisecond to a second, significantly limiting the cycle time. In this work, we present fast, 2.

View Article and Find Full Text PDF