Background: Surgical site wound closure plays a vital role in post-operative success. This effect is magnified in regard to commonly performed elective procedures such as total knee arthroplasty. The use of either sutures or staples for skin re-approximation remains a contested subject, which may have a significant impact on both patient safety and surgical outcome. The literature remains divided on this topic.

Methods: Two cohorts of patients at a level one trauma and regional referral center were reviewed. Cohorts consisted of consecutive total knee arthroplasties performed by two surgeons who achieved surgical wound re-approximation by either staples or absorbable subcuticular sutures. Outcome variables included time of surgery, wound dehiscence, surgical site infection per Center for Disease Control criteria and repeat procedures for debridement and re-closure.

Results: 181 patients qualified for study inclusion. Staples were employed in 82 cases (45.3% of total) and sutures in 99 cases (54.7%). The staples group had no complications while the sutures group had 9 (9.1%). These consisted of: 4 infections (2 superficial, one deep, one organ/space); three patients required re-suturing for dehiscence; one allergic type reaction to suture material; and one gout flare resulting in dehiscence. The mean surgical time with sutures was 122.3 minutes (sd = 33.4) and with staples was 114 minutes (sd = 24.4).

Conclusion: This study demonstrated significantly fewer complications with staple use than with suture use. While all complications found in this study cannot be directly attributed to skin re-approximation method, the need for further prospective, randomized trials is established.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3212897PMC
http://dx.doi.org/10.1186/1754-9493-5-26DOI Listing

Publication Analysis

Top Keywords

total knee
12
wound closure
8
181 patients
8
surgical site
8
skin re-approximation
8
dehiscence surgical
8
staples
6
surgical
5
sutures
5
modality wound
4

Similar Publications

Background: Meniscal surgery is one of the most frequent orthopaedic procedures performed worldwide. There is a wide range of possible treatment errors that can occur following meniscal surgery. In Norway, patients subject to treatment errors by hospitals and private institutions can file a compensation claim free of charge to the Norwegian System of Patient Injury Compensation (NPE).

View Article and Find Full Text PDF

Objective: This study aims to elucidate the impact of varying tourniquet application timings on postoperative pain and the bone cement interface following TKA.

Method: Patients who underwent TKA in our department between March 2021 and July 2023 were included in this study. They were randomly assigned to three groups: Group 1 used tourniquets throughout the operation, Group 2 applied tourniquets before the osteotomy, and Group 3 applied tourniquets after completing the osteotomy.

View Article and Find Full Text PDF

Background: Evaluating the correlation between degenerative meniscus tears and medial meniscus extrusion is necessary to determine the appropriate treatment plan for early-stage knee osteoarthritis. This study evaluated the relationship between degenerative meniscal tears and medial meniscus extrusion in early-stage knee osteoarthritis by using ultrasonography.

Methods: A total of 132 knees from 123 patients with early-stage knee osteoarthritis were evaluated retrospectively.

View Article and Find Full Text PDF

Background: Previous clinical studies suggest that preserving the anterior cruciate ligament (ACL) is crucial for stable knee motion and long-term longevity of the reconstructed knee. The ACL damage or loss often occurs in advanced medial osteoarthritis (OA). This study aimed to investigate the correlation between ACL damage and varus deformity progression as a risk factor for ACL tears in knee OA.

View Article and Find Full Text PDF

Background: Arthroplasty registries play a critical role in improving the quality of care and performing post-market surveillance of medical devices. We report the Michigan Arthroplasty Registry Collaborative Quality Initiative (MARCQI) findings specific to the Biomet Vanguard XP bicruciate-retaining total knee implant.

Methods: Data were collected from MARCQI's 2019 report (February 15, 2012, through December 31, 2018).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!