A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reconstruction of type II+III pelvic resection with a modular hemipelvic endoprosthesis: a finite element analysis study. | LitMetric

Objective: To conduct a biomechanical study of the whole reconstructed pelvic ring using a modular hemipelvic endoprosthesis.

Methods: A subject-specific finite-element (FE) model of the whole pelvic ring, including the pelvis, sacrum and main ligaments, was constructed. Type II+III pelvic resection was simulated on the FE model. Then a three-dimensional model of a reconstructed pelvic ring with a modular hemipelvic endoprosthesis was developed, and FE analysis performed to compare the stresses along the bilateral arcuate lines of the reconstructed and normal pelvis in the bipedal standing position. Comparison between bilateral stress distributions along the sciatic notch was also performed. The characteristics of load transmission within the endoprosthesis were also studied.

Results: No significant difference in the stresses along the bilateral arcuate lines was observed between the reconstructed and normal pelvis. The stress distribution on the prosthesis along the sciatic notch paths was significantly greater than that on the unaffected side in the same position. The peak stress of the implant on the S1 vertebral body was 182.9 MPa under a load of 600N. Study of load transfer on the implant showed that the posterior side of the column between the point of iliac fixation and the acetabulum was subject to the greatest stress.

Conclusion: This FE study showed that a modular hemipelvic endoprosthesis can restore load transfer between the sacrum and acetabulum on simple standing. Future implant design should aim to decrease the stress concentration and make the biomechanical performance more balanced.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6583553PMC
http://dx.doi.org/10.1111/j.1757-7861.2010.00099.xDOI Listing

Publication Analysis

Top Keywords

modular hemipelvic
16
hemipelvic endoprosthesis
12
pelvic ring
12
type ii+iii
8
ii+iii pelvic
8
pelvic resection
8
reconstructed pelvic
8
ring modular
8
stresses bilateral
8
bilateral arcuate
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!