A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Biomechanical evaluation of stability and three-dimensional movements of the atlantoaxial joint after artificial atlanto-odontoid joint arthroplasty. | LitMetric

Objective: To investigate the stability and three-dimensional movements of the atlantoaxial joint after artificial atlanto-odontoid joint (AAOJ) arthroplasty.

Method: Ten sets of AAOJ implanted in bony specimens from 10 adults were used to test the pull-out strength of the atlas-axis components with a MTS858 Mini Bionix machine. Another twelve human cadaveric specimens including C(0)-C(4) were used to evaluate the three-dimensional movements of C(1)-C(2) under five different conditions in sequence, that is, the complete specimen, anterior decompression, posterior transarticular screws fixation, AAOJ arthroplasty and fatigue test.

Result: There were significant differences between atlas and axis components in the maximum pull-out strength and trajectory length, however the yield length was not significantly different. The maximum pull-out strength of the atlas and axis was positively correlated with trajectory length (r(1)= 0.880, P < 0.05) and yield length (r(2)= 0.606, P < 0.05), respectively. After AAOJ arthroplasty, the range of movement (ROM) with respect to rotation and the neutral zone of the atlantoaxial joint were close to normal (P > 0.05), but the ROM in flexion-extension and lateral bending was significantly smaller compared with the specimens which underwent anterior decompression (P < 0.05). No abrasion and abnormal mobilization were observed after 2000 cycles of flexion, extension, lateral bending and axial rotation in the fatigue test.

Conclusions: The self-designed AAOJ has excellent biomechanical performance, and AAOJ arthroplasty can restore excellent instant stability and preserve the movement of the atlantoaxial joint.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6583174PMC
http://dx.doi.org/10.1111/j.1757-7861.2010.00073.xDOI Listing

Publication Analysis

Top Keywords

atlantoaxial joint
16
three-dimensional movements
12
pull-out strength
12
aaoj arthroplasty
12
stability three-dimensional
8
movements atlantoaxial
8
joint artificial
8
artificial atlanto-odontoid
8
atlanto-odontoid joint
8
anterior decompression
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!