Objective: To evaluate the safety and efficacy of locking plate combined with bone grafting in the treatment of aseptic nonunion following intramedullary nailing fixation of fractures of the long bones.
Methods: Thirty-eight consecutive patients treated in our hospital between January 2004 and December 2006 were included in this retrospective study. The nonunions included 20 femurs, 15 tibias, and 3 humeri. The duration of non-union ranged from 6 to 84 months and 21 (55.3%) of them were located around the metaphysis of the affected long bones. There were 12 women and 26 men with a mean age of 39.2 years (range, 9-70 years). Locking plate combined with bone grafting was the procedure chosen to treat every case of nonunion in this series. The clinical outcomes were evaluated.
Results: All patients were followed up for 6-20 months (average 11.6 months). After locking plate fixation combined with bone grafting, union was achieved in all cases, the average healing time being 5.3 months (range, 4-8 months). Infection of the superficial incision occurred in three cases (7.9%) and delayed healing of the incision in one case, all of which healed with no further complications. The function of the adjacent joints was excellent to good in 30 patients (78.9%), fair in 7 (18.4%) and poor in 1 (2.6%) after follow-up.
Conclusion: Locking plate fixation combined with bone grafting is a highly effective treatment for aseptic nonunions of the long bones after intramedullary nailing fixation, especially in the case of metaphyseal nonunion.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6583635 | PMC |
http://dx.doi.org/10.1111/j.1757-7861.2009.00040.x | DOI Listing |
Medicina (Kaunas)
January 2025
Department of Orthopedic Surgery, Anam Hospital, Korea University College of Medicine, 73 Goryeodae-ro Seongbuk-gu, Seoul 02841, Republic of Korea.
Distal tibia fractures are high-energy injuries characterized by a mismatch between standard plate designs and the patient's specific anatomical bone structure, which can lead to severe soft tissue damage. Recent advancements have focused on the development of customized metal plates using three-dimensional (3D) printing technology. However, 3D-printed metal plates using titanium alloys have not incorporated a locking system due to the brittleness of these alloys.
View Article and Find Full Text PDFMedicina (Kaunas)
January 2025
Department of Orthopedics and Traumatology, Karabük University, Karabük 78050, Turkey.
The study aimed to evaluate a newly designed semicircular implant for the fixation of Vancouver Type B1 periprosthetic femoral fractures (PFFs) in total hip arthroplasty (THA) patients. To determine its strength and clinical applicability, the new implant was compared biomechanically with conventional fixation methods, such as lateral locking plate fixation and a plate combined with cerclage wires. : Fifteen synthetic femur models were used in this biomechanical study.
View Article and Find Full Text PDFEur J Trauma Emerg Surg
January 2025
Bowen University Teaching Hospital, P. O. Box 15, Ogbomoso, Oyo State, Nigeria.
Purpose: To investigate the factors that prolonged the operative duration (OD) in patients who underwent single-stage locked intramedullary nailing of their multiple concurrent long-bone fractures (LBFs) using Surgical Implant Generation Network (SIGN) nails.
Methods: Forty-nine patients who fulfilled the inclusion criteria were enrolled prospectively over 8½ years. Data collected included age, sex, injury mechanism and severity, fracture characteristics, nail types and diameter, OD, fracture-to-fixation time, length of hospital stay (LOS), functional outcomes and complications.
Arch Orthop Trauma Surg
January 2025
Department of Orthopaedics, Wright State University, 30 E Apple St., Suite 2200, Dayton, OH, 45409, USA.
Introduction: We propose and assess the biomechanical stability of medial column screw supplementation in a synthetic distal femur fracture model.
Materials And Methods: Twenty-four low density synthetic femora modeling osteoporotic, intraarticular distal femur fractures with medial metaphyseal comminution were split into two fixation groups: (1) lateral locking distal femur plate (PA- plate alone) and (2) lateral locking distal femur plate with a 6.5 mm fully threaded medial cannulated screw (PWS- plate with screw).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!