A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparing peak and submaximal cardiorespiratory responses during field walking tests with incremental cycle ergometry in COPD. | LitMetric

Background And Objective: Field and laboratory-based tests are used to measure exercise capacity in people with COPD. A comparison of the cardiorespiratory responses to field tests, referenced to a laboratory test, is needed to appreciate the relative physiological demands. We sought to compare peak and submaximal cardiorespiratory responses to the 6-min walk test, incremental shuttle walk test and endurance shuttle walk test with a ramp cycle ergometer test (CET) in patients with COPD.

Methods: Twenty-four participants (FEV(1) 50 ± 14%; 66.5 ± 7.7 years; 15 men) completed four sessions, separated by ≥24 h. During an individual session, participants completed either two 6-min walk tests, incremental shuttle walk tests, endurance shuttle walk tests using standardized protocols, or a single CET, wearing a portable gas analysis unit (Cosmed K4b(2)) which included measures of heart rate and arterial oxygen saturation (SpO(2)).

Results: Between tests, no difference was observed in the peak rate of oxygen uptake (F(3,69) = 1.2; P = 0.31), end-test heart rate (F(2,50) = 0.6; P = 0.58) or tidal volume (F(3,69) = 1.5; P = 0.21). Compared with all walking tests, the CET elicited a higher peak rate of carbon dioxide output (1173 ± 350 mL/min; F(3,62) = 4.8; P = 0.006), minute ventilation (48 ± 17 L/min; F(3,69) = 10.2; P < 0.001) and a higher end-test SpO(2) (95 ± 4%; F(3,63) = 24.9; P < 0.001).

Conclusions: In patients with moderate COPD, field walking tests elicited a similar peak rate of oxygen uptake and heart rate as a CET, demonstrating that both self- and externally paced walking tests progress to high intensities.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1440-1843.2011.02089.xDOI Listing

Publication Analysis

Top Keywords

walking tests
16
shuttle walk
16
cardiorespiratory responses
12
walk test
12
walk tests
12
heart rate
12
peak rate
12
tests
10
peak submaximal
8
submaximal cardiorespiratory
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!