This study investigates the use of features extracted from intramuscular electromyography (EMG) for estimating grasping force in the ipsilateral and contralateral (mirrored) hand, during bilateral grasping tasks. This is relevant since force estimation using mirror tasks is a potentially useful pathway for the clinical training of unilateral amputees. Bilateral grasping force and intramuscular EMG (wire electrodes) of the right forearm were measured in 10 able-bodied subjects. The features extracted from the EMG signal were the root mean square, the global discharge rate, the standard sample entropy, and the constraint sample entropy (CSE). The association between the EMG features and force was modeled using a first-order polynomial model, a second-order exponential model, and an artificial neural network (ANN). The accuracies of estimation of ipsilateral and mirrored grasping force were not significantly different (e.g., R(2) = 0.89 ± 0.02 for ipsilateral and 0.88 ± 0.017 for mirrored, when using CSE and the ANN). It was concluded that it is possible to use just one channel of intramuscular EMG for force estimation. This result suggests that intramuscular EMG signals may be suitable for proportional myoelectric control and that training of the association between intramuscular EMG features and force can be performed using mirror tasks, which is a needed condition for applications in unilateral amputees.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10439-011-0438-7 | DOI Listing |
Clin Neurophysiol Pract
December 2024
NeuRAL Lab, Abbott Neuromodulation, Plano, TX 75024, USA.
Objective: This study aims to investigate the sources of later response in epidural spinal recordings (ESRs) obtained from implanted leads during spinal cord stimulation, a topic has not been widely studied in previous research.
Methods: Two patients with lower back and lower extremity pain underwent SCS implantation with intraoperative neuromonitoring (IONM). The timing of extracted peaks in ESRs and intramuscular electromyography (EMG) recordings were analyzed and compared to a Monte Carlo simulation for synchronization analysis.
J Neurophysiol
January 2025
School of Kinesiology, Faculty of Health Sciences, The University of Western Ontario, London, ON, Canada.
The purpose was to assess whether visual feedback of torque contributes to motor unit (MU) firing rate reduction observed during post-activation potentiation (PAP) of skeletal muscle. From 15 participants 23 MUs were recorded with intramuscular fine-wire electrodes from the tibialis anterior during isometric dorsiflexion contractions at 20% of maximum, with and without both PAP and visual feedback of torque. A 5s maximal voluntary contraction (MVC) was used to induce PAP, and evoked twitch responses were assessed before and after.
View Article and Find Full Text PDFSkelet Muscle
December 2024
Laboratory of Exercise and Health, ETH Zurich, Schwerzenbach, Switzerland.
Background: Hip osteoarthritis patients display higher levels of fatty infiltration (FI) in the gluteus minimus (GM) compared to other hip muscles. We investigated specific histological factors such as fiber type composition and collagen deposition, and functional outcomes like muscle strength and activation associated with FI in these patients.
Methods: In twelve men (67 ± 6 y) undergoing total hip replacement (THR), hip and knee muscle strength and activation (electromyography, EMG) were assessed bilaterally.
J Appl Biomech
February 2025
School of Kinesiology and Health Science, York University, Toronto, ON, Canada.
Intramuscular (iEMG) and surface electromyographic (sEMG) signals have been compared previously using predictive regression equations, finite element modeling, and correlation and cross-correlation analyses. Although subcutaneous fat thickness (SCFT) has been identified as a primary source of sEMG signal amplitude attenuation and low-pass filter equivalence, few studies have explored the potential effect of SCFT on sEMG and iEMG signal characteristics. The purpose of this study was to investigate the relationship between normalized submaximal iEMG and sEMG signal amplitudes collected from 4 muscles (rectus femoris, vastus lateralis, infraspinatus, and erector spinae) and determine whether SCFT explains more variance in this relationship.
View Article and Find Full Text PDFJ Vis Exp
November 2024
Department of Semiconductor Engineering, Gachon University; Department of Electronic Engineering, Gachon University;
The intramuscular electromyography (EMG) measurement method for experimental animals has been implemented in various ways. Among these methods, tethering cables to external measurement devices can restrict the movement of experimental animals, while implantable devices may cause unwanted side effects due to the constant presence of a device with considerable size and weight. To address these issues, we propose a low-cost, wireless, detachable EMG measurement system and experimental procedure.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!