A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Rapid detection of erythropoiesis-stimulating agents in urine and serum. | LitMetric

Rapid detection of erythropoiesis-stimulating agents in urine and serum.

Anal Biochem

Department of Physical and Analytical Chemistry, Uppsala University, SE-751 24 Uppsala, Sweden.

Published: January 2012

A rapid and easy-to-use test kit, EPO WGA MAIIA, which can be used for distinguishing various endogenous human erythropoietins (hEPOs) and several recombinant hEPO and EPO analogues, has been evaluated. The test is based on chromatographic separation of the glycosylated isoforms of EPO using wheat germ agglutinin (WGA) and a sensitive immunoassay using anti-EPO carbon black nanostrings and image scanning for quantification. All of the reactions take place along the porous layer of a lateral flow microcolumn containing WGA and anti-EPO zones. The presence of molecules resembling hEPOs, such as Mircera, was detected by the aberrant affinity interaction with the antibody zone on the strip. It was possible to distinguish nine recombinant hEPOs expressed in hamster and human cell lines, as well as Aranesp and Mircera, from endogenous urine hEPO. The required amount of EPO in the samples, a few picograms, is very low compared with other methods for EPO isoform identification. This EPO isoform determination method opens the possibility to monitor recombinant EPO therapy for clinical research and seems to be a valuable candidate to the arsenal of EPO doping control tests.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ab.2011.09.021DOI Listing

Publication Analysis

Top Keywords

epo
8
epo isoform
8
rapid detection
4
detection erythropoiesis-stimulating
4
erythropoiesis-stimulating agents
4
agents urine
4
urine serum
4
serum rapid
4
rapid easy-to-use
4
easy-to-use test
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!