Detection and identification of alkylphosphonic acids by positive electrospray ionization tandem mass spectrometry using a tricationic reagent.

Rapid Commun Mass Spectrom

Vertox Laboratory, Defence Research and Development Establishment, Gwalior, India.

Published: November 2011

The retrospective detection and identification of degradation products of chemical warfare agents are of immense importance in order to prove their spillage and use. A highly sensitive liquid chromatography/electrospray ionization tandem mass spectrometric (LC/ESI-MS/MS) method--using an imidazolium-based tricationic reagent--was developed for the detection and identification of the anionic degradation products of nerve agents. A commercially available solution of 1,3-imidazolium-bis-(1-hexylbenzylimidazolium) trifluoride (IBHBI) formed adducts with alkylphosphonic acids (APAs), allowing detection of the APAs by positive mode ESI-MS. Tandem mass spectrometry was used for the unambiguous identification of the APAs. Parameters influencing the formation and stability of these adduct during mass spectrometric analysis, such as solvent composition, concentration of IBHBI, effect of pH and interferences by salts, were optimized. The absolute limits of detection (0.1 ng) for achieved for the APAs were better than those previously reported, and linear dynamic ranges of 10-2000 ng mL(-1) were achieved. The method was repeatable with a relative standard deviation ≤7.3%. APAs present in aqueous samples provided by the Organization for the Prohibition of Chemical Weapons during the 22(nd) and 24(th) Official Proficiency tests were detected and identified as IBHBI adducts. The added advantage of this method is that low-mass analytes are detected at higher mass, thus obviating the problem with background noise at low mass.

Download full-text PDF

Source
http://dx.doi.org/10.1002/rcm.5244DOI Listing

Publication Analysis

Top Keywords

detection identification
12
tandem mass
12
alkylphosphonic acids
8
ionization tandem
8
mass spectrometry
8
degradation products
8
mass spectrometric
8
mass
6
detection
5
apas
5

Similar Publications

This systematic review and meta-analysis aimed to assess the accuracy and success rate of ultrasound in determining fetal sex. A search was conducted on Medline, Cochrane Library, and EMBASE databases, and the reference lists of selected studies were also reviewed. Meta-analyses were performed using Revman 5.

View Article and Find Full Text PDF

Nitrogen@Carbon quantum dots (N@CQDs) are prepared using microwave hydrothermal method, and polyvinylpyrrolidone (PVP) and melamine are used as mixed C source and N source. Microwave reaction conditions of preparing the N@CQDs are 170 ℃ and 3 h. This N@CQDs are are used as fluorescence probe for detection of amino acids.

View Article and Find Full Text PDF

Michael and Schiff-Base Reactions-Assisted Fluorescence Sensor Based on the MOF Nanosheet Microspheres for the Effective Discrimination and Detection of Hydroquinone and Catechol.

Anal Chem

January 2025

Center of Advanced Analysis and Gene Sequencing, Key Laboratory of Molecular Sensing and Harmful Substances Detection Technology, Zhengzhou University, Kexue Avenue 100, Zhengzhou, Henan 450001, P. R. China.

A novel sensing platform was constructed for the recognition and identification of dihydroxybenzene isomers based on the MOF-0.02TEA fluorescence sensor with the morphology of nanosheet microspheres through coordination modulation. Based on the sensing principle that the amino group on the MOF-0.

View Article and Find Full Text PDF

Glutathione serves as a common biomarkers in tumor diagnosis and treatment. The levels of its intracellular concentration permit detailed investigation of the tumor microenvironment. However, low polarization and weak Raman scattering cross-section make direct and indirect Raman detection challenging.

View Article and Find Full Text PDF

Background: Multianalyte machine learning (ML) models can potentially identify previously undetectable wrong blood in tube (WBIT) errors, improving upon current single-analyte delta check methodology. However, WBIT detection model performance has not been assessed in a real-world, low-prevalence context. To estimate real-world positive predictive values, we propose a methodology to assess WBIT detection models by evaluating the impact of missing data and by using a "low prevalence" validation data set.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!