Ecotoxicology research is using many methods for engineered nanomaterials (ENMs), but the collective experience from researchers has not been documented. This paper reports the practical issues for working with ENMs and suggests nano-specific modifications to protocols. The review considers generic practical issues, as well as specific issues for aquatic tests, marine grazers, soil organisms, and bioaccumulation studies. Current procedures for cleaning glassware are adequate, but electrodes are problematic. The maintenance of exposure concentration is challenging, but can be achieved with some ENMs. The need to characterize the media during experiments is identified, but rapid analytical methods are not available to do this. The use of sonication and natural/synthetic dispersants are discussed. Nano-specific biological endpoints may be developed for a tiered monitoring scheme to diagnose ENM exposure or effect. A case study of the algal growth test highlights many small deviations in current regulatory test protocols that are allowed (shaking, lighting, mixing methods), but these should be standardized for ENMs. Invertebrate (Daphnia) tests should account for mechanical toxicity of ENMs. Fish tests should consider semistatic exposure to minimize wastewater and animal husbandry. The inclusion of a benthic test is recommended for the base set of ecotoxicity tests with ENMs. The sensitivity of soil tests needs to be increased for ENMs and shortened for logistics reasons; improvements include using Caenorhabditis elegans, aquatic media, and metabolism endpoints in the plant growth tests. The existing bioaccumulation tests are conceptually flawed and require considerable modification, or a new test, to work for ENMs. Overall, most methodologies need some amendments, and recommendations are made to assist researchers.

Download full-text PDF

Source
http://dx.doi.org/10.1002/etc.706DOI Listing

Publication Analysis

Top Keywords

methods engineered
8
engineered nanomaterials
8
enms
8
practical issues
8
tests
7
ecotoxicity test
4
methods
4
test methods
4
nanomaterials practical
4
practical experiences
4

Similar Publications

TiRobot-assisted versus freehand femoral neck system placement in the treatment of femoral neck fractures: a systematic review and meta-analysis.

J Robot Surg

January 2025

The Third Ward of Orthopaedic Department, General Hospital of Ningxia Medical University, 804 Shengli South Street, Hui Autonomous Region, Yinchuan, Ningxia, 750004, People's Republic of China.

The purpose of this study is to assess the safety and effectiveness of TiRobot-assisted treatment for femoral neck fractures, in comparison to traditional freehand treatment methods. Throughout the research process, we conducted an extensive literature search across numerous databases, including PubMed, EMBASE, Cochrane Library, Web of Science, China National Knowledge Infrastructure (CNKI), CQVIP, and Wanfang. Based on the literature screening criteria, we selected six studies, encompassing 358 cases of femoral neck fracture patients, for this meta-analysis.

View Article and Find Full Text PDF

Background Aims: Extracellular vesicles (EVs) have gained traction as potential cell-free therapeutic candidates. Development of purification methods that are scalable and robust is a major focus of EV research. Yet there is still little in the literature that evaluates purification methods against potency of the EV product.

View Article and Find Full Text PDF

A Randomized, Controlled Trial of In-Hospital Use of Virtual Reality to Reduce Preoperative Anxiety Prior to Cardiac Surgery.

Mayo Clin Proc

January 2025

Departments of Cardiovascular Surgery, Mayo Clinic, Rochester, MN, USA; Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA; Robert and Arlene Kogod Center on Aging, Mayo Clinic, Rochester, MN, USA. Electronic address:

Objective: To study the effectiveness of virtual reality (VR) in reducing anxiety levels in patients undergoing first-time sternotomy for cardiac surgery.

Patients And Methods: A total of 100 adult patients scheduled for cardiac surgery at Mayo Clinic in Rochester, Minnesota, USA, was recruited from April 19, 2022, to October 12, 2022. Before surgery, patients wore a physiological monitor to record vital signs.

View Article and Find Full Text PDF

Purpose: Current technologies to define the zone of acute peripheral nerve injury intraoperatively are limited by surgical experience, time, cumbersome electrodiagnostic equipment, and interpreter reliability. In this pilot study, we evaluated a real-time, label-free optical technique for intraoperative nerve injury imaging. We hypothesize that fluorescence lifetime imaging (FLIm) will detect a difference between the time-resolved fluorescence signatures for acute crush injuries versus uninjured segments of peripheral nerves in sheep.

View Article and Find Full Text PDF

Powder X-ray diffraction (PXRD) is a prevalent technique in materials characterization. While the analysis of PXRD often requires extensive human manual intervention, and most automated method only achieved at coarse-grained level. The more difficult and important task of fine-grained crystal structure prediction from PXRD remains unaddressed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!