A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Sutureless transconjunctival 20-gauge vitrectomy]. | LitMetric

[Sutureless transconjunctival 20-gauge vitrectomy].

J Fr Ophtalmol

Service d'ophtalmologie, centre de la rétine, centre hospitalo-universitaire de Toulouse, 330, avenue de Grande-Bretagne, TSA 70034, 31059 Toulouse cedex 9, France.

Published: December 2011

Purpose: To evaluate the safety and efficacy of 20-gauge transconjunctival sutureless vitrectomy for a variety of vitreoretinal conditions.

Patients And Methods: This study was a retrospective clinical case series examining 29 eyes of 29 patients treated with 20-gauge transconjunctival sutureless vitrectomy. The main outcome measures included intraocular pressure, visual acuity, surgical time, and intraoperative and postoperative complications.

Results: The mean follow-up duration was 5.7 months. There were only two cases of postoperative ocular hypotony (6.9%) and one suspect case of endophthalmitis. Mean overall acuity improved from 0.495 logMar at baseline to 0.29 logMar (p=0.002) and mean total operative time was 19 min. We observed no cases of retinal detachment.

Conclusion: Twenty-gauge transconjunctival sutureless vitrectomy is an effective surgical technique, but other studies are needed to confirm its safety and its value in other indications.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jfo.2011.04.021DOI Listing

Publication Analysis

Top Keywords

transconjunctival sutureless
12
sutureless vitrectomy
12
20-gauge transconjunctival
8
[sutureless transconjunctival
4
transconjunctival 20-gauge
4
20-gauge vitrectomy]
4
vitrectomy] purpose
4
purpose evaluate
4
evaluate safety
4
safety efficacy
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!