A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Multiplex isothermal helicase-dependent amplification assay for detection of Chlamydia trachomatis and Neisseria gonorrhoeae. | LitMetric

Multiplex isothermal helicase-dependent amplification assay for detection of Chlamydia trachomatis and Neisseria gonorrhoeae.

Diagn Microbiol Infect Dis

QIAGEN North America, Research and Development, QIAGEN Inc., Gaithersburg, MD 20878, USA.

Published: December 2011

Thermophilic helicase dependent amplification (tHDA), which employs helicase to unwind double-stranded DNA at constant temperature, is a relatively new isothermal nucleic acid amplification technology. In this study, the development and optimization of a 4-plex tHDA assay for detection of Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) are described. tHDA is combined with sequence-specific sample preparation on magnetic beads and homogeneous endpoint fluorescence detection using dual-labeled probes. This 4-plex tHDA assay was applied to the detection of 2 genes on CT and a multicopy gene on NG in the presence of an internal control. The assay showed high analytical sensitivity and specificity of simultaneous CT/NG detection and is compatible with a wide variety of sample types and media. The isothermal reaction conditions and homogeneous endpoint detection utilized in this assay are well suited for laboratory automation and high-throughput screening applications as well as for point-of-care testing.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.diagmicrobio.2011.08.021DOI Listing

Publication Analysis

Top Keywords

assay detection
8
detection chlamydia
8
chlamydia trachomatis
8
trachomatis neisseria
8
neisseria gonorrhoeae
8
4-plex thda
8
thda assay
8
homogeneous endpoint
8
detection
6
assay
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!