Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 144
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3106
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Aims: We investigated the relationship between arrhythmia burden, left atrial volume (LAV) and N-terminal pro-B-type natriuretic peptide (NT-pro-BNP) at baseline and after long-term follow-up of atrial fibrillation (AF) ablation.
Methods: We studied 38 patients (23 paroxysmal, 6 women, mean age 56 ± 11) scheduled for AF ablation. LAV was calculated on the basis of computed tomography images at baseline and long-term follow-up, and arrhythmia burden was graded from self-reported frequency and duration of AF episodes.
Results: After a mean period of 22 ± 5 months, 28/38 patients (11/15 persistent) were free from AF recurrence. At baseline there were no differences in mean LAV (125 vs. 130 cm(3), p = 0.7) or median NT-pro-BNP (33.5 vs. 29.5 pmol/L, p = 0.9) between patients whose ablation had been successful or otherwise. At long-term follow-up, there was a marked decrease in LAV (105 vs. 134 cm(3), p < 0.05) and level of NT-pro-BNP (7 vs. 17.5 pmol/L, p < 0.05) in the successful ablation patients. NT-pro-BNP correlated with LAV both at baseline (r = 0.71, p < 0.001) and at follow-up (r = 0.57, p < 0.001). Arrhythmia burden correlated with both NT-pro-BNP (r = 0.47, p < 0.01) and LAV (r = 0.52, p < 0.01). A decrease in NT-pro-BNP at follow-up of >25% of baseline value had a specificity of 0.89 and a sensitivity of 0.6 (receiver operator characteristics, accuracy 0.82) for ablation success.
Conclusions: NT-pro-BNP correlates with LAV and arrhythmia burden in AF patients and both NT-pro-BNP and LAV decrease significantly after successful ablation. A decrease in NT-pro-BNP of >25% from the baseline value could be useful as a marker of ablation success.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10840-011-9629-2 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!