Aims: Atrial fibrillation (AF) is a major cause of morbidity, mortality, and health resource consumption. However, as many patients with chronic AF are asymptomatic, rapid, accurate opportunistic screening is needed in primary care to detect AF. Conventional electrocardiogram (ECG) technology is too clumsy and time consuming for mass opportunistic screening, thus technology that allows easy, rapid, yet accurate AF screening is required. To address this requirement a prototype hand-held electrode assembly was developed. We hypothesized that a 6-lead frontal-plane ECG acquired from this apparatus in a seated, clothed patient would be as accurate at detecting AF as conventional 12-lead ECG in the undressed, supine patient (the 'gold standard').
Methods And Results: Electrocardiograms were obtained from 78 patients with AF and 79 with sinus rhythm (SR). All had a conventional 12-lead ECG, a 6-lead ECG from conventionally positioned limb electrodes, a supine 6-lead recording using the prototype recorder placed on the lower thorax/upper abdomen, and a 6-lead prototype recording in the seated patient, the latter with loosened clothing only. Electrocardiograms were randomly and blindly assessed by two cardiologists for (i) diagnosis of AF vs. SR and (ii) tracing quality (subjectively assessed as good, adequate, or bad). Compared with conventional 12-lead ECG recordings, all 'new' recording methods performed satisfactorily with sensitivities ≥90% (90-99%), specificities ≥94% (94-100%), positive predictive values ≥94% (94-100%), negative predictive values ≥90% (90-99%), and accuracies ≥93% (93-99%). Tracing quality was higher in conventional 12-lead recordings (71 and 80% were assessed as good by the two observers) compared with conventional 6-lead (57 and 59%), supine prototype (41 and 31%), and sitting prototype (39 and 19%).
Conclusions: Despite inferior electrocardiographic quality a 6-lead frontal plane ECG acquired by a simple prototype hand-held electrode assembly allowed reliable differentiation of AF from SR compared with standard 12-lead ECG.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/europace/eur304 | DOI Listing |
Ann Noninvasive Electrocardiol
January 2025
Department of Cardiology, Xinhua Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
Objective: To compare the paced QRS duration on different sites in age-, gender-, and indication-matched patients implanted with Micra leadless pacemakers and conventional transvenous pacemakers (TV-PM).
Method: A total of 82 patients from Xinhua Hospital, Shanghai Jiaotong University, were enrolled, including two groups of 41 patients matched according to gender, age, and pacemaker indications, who underwent Micra and TV-PM implantations, respectively. The baseline data of the patients, the pacing site described using three- and nine-partition methods, and the paced QRS duration on 12-lead electrocardiogram were then analyzed.
Med Image Anal
January 2025
Department of Engineering Science, University of Oxford, Oxford, UK.
Cardiac digital twins (CDTs) offer personalized in-silico cardiac representations for the inference of multi-scale properties tied to cardiac mechanisms. The creation of CDTs requires precise information about the electrode position on the torso, especially for the personalized electrocardiogram (ECG) calibration. However, current studies commonly rely on additional acquisition of torso imaging and manual/semi-automatic methods for ECG electrode localization.
View Article and Find Full Text PDFJ Mol Cell Cardiol Plus
March 2024
Department of Physiology and Cardiology, the Netherlands.
This paper reviews the literature on assessing electrical dyssynchrony for patient selection in cardiac resynchronization therapy (CRT). The guideline-recommended electrocardiographic (ECG) criteria for CRT are QRS duration and morphology, established through inclusion criteria in large CRT trials. However, both QRS duration and LBBB morphology have their shortcomings.
View Article and Find Full Text PDFEur Heart J Acute Cardiovasc Care
January 2025
Department of Medical Informatics, Korea University College of Medicine, Seoul, Republic of Korea.
Background: Acute heart failure (AHF) poses significant diagnostic challenges in the emergency room (ER) because of its varied clinical presentation and limitations of traditional diagnostic methods. This study aimed to develop and evaluate a deep-learning model using electrocardiogram (ECG) data to enhance AHF identification in the ER.
Methods: In this retrospective cohort study, we analyzed the ECG data of 19,285 patients who visited ERs of three hospitals between 2016 and 2020; 9,119 with available left ventricular ejection fraction and N-terminal prohormone of brain natriuretic peptide level data and who were diagnosed with AHF were included in the study.
Cardiol Young
December 2024
Children's Mercy Hospital, Kansas City, MO, USA.
Introduction: Alternate electrocardiogram acquisition with fewer leads lacks systematic evaluation in children. This study aims to determine if electrocardiograms with fewer leads maintain diagnostic accuracy in paediatrics.
Methods: This is a single-centre review of 200 randomly selected standard 12-lead electrocardiograms from our hospital database (2017-2020) for patients aged 2 weeks to 21 years.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!