A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Sustainability of critical power determined by a 3-minute all-out test in elite cyclists. | LitMetric

Sustainability of critical power determined by a 3-minute all-out test in elite cyclists.

J Strength Cond Res

Human Performance Laboratory, Department of Exercise Science, California Lutheran University, Thousand Oaks, California, USA.

Published: November 2011

Critical power (CP) is a theoretical workload representative of an athlete's maximal sustainable pace. Recent research has validated a 3-minute all-out test on a cycle ergometer for determining CP; however, few studies have investigated the sustainability of CP using this test. The purpose of this study was to determine the sustainability of CP established during the 3-minute test and the determinants of sustainability. A group of elite cyclists (N = 21) performed a VO2max test, 3-minute all-out test, and a time to exhaustion (TTE) trial at CP on 3 different days separated by at least 24 hours. Expired gases were collected during all trials and analyzed for VO2 and VCO2. Heart rate was measured by telemetry. Multiple regression was used to determine predictors of sustainability with significance predetermined at p < 0.05. VO2max was measured at 58.9 ± 5.6 ml·kg(-1)·min(-1), ventilation breakpoint at 44.9 ± 5.7 ml·kg(-1)·min(-1) (75% VO2max), and maximum heart rate at 179 ± 10 b·min(-1). Peak power (PP) in the 3-minute all-out test was measured at 738 ± 170 W, and CP was determined at 305 ± 32 W or 79% of VO2max. The VO2 at CP was 55.4 ± 6.9 ml·kg(-1)·min(-1), representing 94% of measured VO2max. The mean TTE at CP was 14.79 ± 8.38 minutes. The difference score of PP - CP significantly predicted TTE (r = 0.65, p < 0.05). No other measured variables contributed to this prediction. Based on sustainability, these data suggest that the 3-minute all-out test may overestimate CP in elite cyclists, which could lead to overtraining if CP determined with this test is used to identify training intensities.

Download full-text PDF

Source
http://dx.doi.org/10.1519/JSC.0b013e318212dafcDOI Listing

Publication Analysis

Top Keywords

3-minute all-out
20
all-out test
20
elite cyclists
12
test
9
critical power
8
heart rate
8
sustainability
6
3-minute
6
all-out
5
vo2max
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!