Clinical validation of computer-assisted navigation in total hip arthroplasty.

Adv Orthop

Laboratoire de Recherche en Orthopédie, Hôpital du Sacré-Cœur de Montréal, 5400 Boulevard Gouin Ouest, Locales K-3115, Montréal, QC, Canada H4J 1C5.

Published: November 2011

A CT-based navigation system is helpful to evaluate the reamer shaft and the impactor position/orientation during unilateral total hip arthroplasty (THA). The main objective of this study is to determine the accuracy of the Navitrack system by measuring the implant's true anteversion and inclination, based on pre- and postoperative CT scans (n = 9 patients). The secondary objective is to evaluate the clinical validity of measurements based on postop anteroposterior (AP) radiographs for determining the cup orientation. Postop CT-scan reconstructions and postop planar radiographs showed no significant differences in orientation compared to peroperative angles, suggesting a clinical validity of the system. Postoperative AP radiographs normally used in clinic are acceptable to determine the cup orientation, and small angular errors may originate from the patient position on the table.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3170735PMC
http://dx.doi.org/10.4061/2011/171783DOI Listing

Publication Analysis

Top Keywords

total hip
8
hip arthroplasty
8
clinical validity
8
cup orientation
8
clinical validation
4
validation computer-assisted
4
computer-assisted navigation
4
navigation total
4
arthroplasty ct-based
4
ct-based navigation
4

Similar Publications

Theoretically, animals with longer hindlimbs are better jumpers, while those with shorter hindlimbs are better maneuverers. Yet experimental evidence of this relationship in mammals is lacking. We compared jump force and maneuverability in a lab population of Mongolian gerbils (Meriones unguiculatus).

View Article and Find Full Text PDF

Subtrochanteric fractures in older patients are typically due to low-energy falls. The standard of care is intramedullary nailing. The Smith & Nephew Trigen Intertan (Memphis, TN, US) is an intramedullary nail with a novel design that incorporates two integrated compression screws.

View Article and Find Full Text PDF

Purpose Low-dose total skin electron beam therapy (LD-TSEBT) has recently gained popularity in treating mycosis fungoides (MF) due to its reduced toxicity and favorable response rates. Combining accelerated LD-TSEBT with the modified Stanford technique (mST), a condensed cycling approach, offers a promising and convenient option. However, in vivo dosimetry data confirming the effectiveness of this approach is limited.

View Article and Find Full Text PDF

Introduction: Hip fractures are common and are a major cause of significant morbidity and mortality in the elderly population, particularly when treatment is delayed. The British Orthopaedic Association's (BOA) guidelines state that surgical treatment should be performed within 36 hours of admission. This study aimed to investigate the effects of delays in surgery on clinical outcomes and to evaluate mortality rates over a three-year follow-up period following proximal femoral fractures.

View Article and Find Full Text PDF

Purpose: The Coronavirus Disease 2019 (COVID-19) pandemic delayed elective procedures such as total joint arthroplasty. As surgical volumes return to prepandemic levels, understanding the implications of COVID-19 becomes imperative. This study explored the effects of COVID-19 on the short-term outcomes of hip arthroplasty.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!