Undulating microcatheter tip motion with respiratory cycle during intracranial aneurysm embolization: description of a case and strategy for its mitigation.

J Neurointerv Surg

Division of Interventional Neuroradiology, Russell H Morgan Department of Radiology, Johns Hopkins Hospital, Baltimore, Maryland 21287, USA.

Published: May 2012

The present report describes a technique for mitigating respiration-related microcatheter motion during endovascular aneurysm treatment by modulating ventilator settings. A rare phenomenon of microcatheter tip movement related to respiration is demonstrated. An adjustment of tidal volume and respiratory rate reduced the degree of inspiratory vessel elongation and stabilized the microcatheter position, allowing for safer, more precise coil deployment. This maneuver can easily be applied to other endovascular procedures for which aberrant microcatheter motion must be minimized.

Download full-text PDF

Source
http://dx.doi.org/10.1136/neurintsurg-2011-010060DOI Listing

Publication Analysis

Top Keywords

microcatheter motion
12
undulating microcatheter
4
motion respiratory
4
respiratory cycle
4
cycle intracranial
4
intracranial aneurysm
4
aneurysm embolization
4
embolization description
4
description case
4
case strategy
4

Similar Publications

Purpose: 360-degree gonioscopy-assisted transluminal trabeculotomy (GATT) is a safe and effective angle-based intervention to lower IOP. Use of the iTrack Advance allows the surgeon to efficiently advance the microcatheter in one continuous motion with a slider, an improvement upon previous techniques in which microcatheters or sutures which had to be manually threaded through Schlemm's canal with microforceps. This report demonstrates three variations in surgical technique for successful 360-degree GATT using the iTrack Advance.

View Article and Find Full Text PDF

Medical microrobots in reproductive medicine from the bench to the clinic.

Nat Commun

February 2023

Micro- and NanoBiomedical Engineering Group (MNBE) Institute for Integrative Nanosciences, Leibniz Institute for Solid State and Materials Research (IFW), 01069, Dresden, Germany.

Medical microrobotics is an emerging field that aims at non-invasive diagnosis and therapy inside the human body through miniaturized sensors and actuators. Such microrobots can be tethered (e.g.

View Article and Find Full Text PDF

In this study, we sought to evaluate changes in peritumoral fibrosis after transarterial chemoembolization (TACE) in a rabbit VX2 liver tumor model using intravoxel incoherent motion diffusion-weighted imaging (IVIM DWI) and ultrasound shear wave elastography (SWE). A total of 20 rabbits underwent implantation of VX2 tumor tissues in the left lobe of the liver. The rabbits were randomly divided into an experimental group ( = 10) or a control group ( = 10).

View Article and Find Full Text PDF

Catheters integrated with microcoils for electromagnetic steering under the high, uniform magnetic field within magnetic resonance (MR) scanners (3-7 Tesla) have enabled an alternative approach for active catheter operations. Achieving larger ranges of tip motion for Lorentz force-based steering have previously been dependent on using high power coupled with active cooling, bulkier catheter designs, or introducing additional microcoil sets along the catheter. This work proposes an alternative approach using a heat-mitigated design and actuation strategy for a magnetic resonance imaging (MRI)-driven microcatheter.

View Article and Find Full Text PDF

Purpose: During hepatic arterial interventions, catheter or guidewire position is determined by referencing or overlaying a previously acquired static vessel roadmap. Respiratory motion leads to significant discrepancies between the true position and configuration of the hepatic arteries and the roadmap, which makes navigation and accurate catheter placement more challenging and time consuming. The purpose of this work was to develop a dynamic respiratory motion compensated device guidance system and evaluate the accuracy and real-time performance in an in vivo porcine liver model.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?