Researchers have increasingly recognized the need to quantify the material properties of primate food items, particularly hardness (H) and stiffness (E), which is measured as elastic modulus. Assessing E in the field is particularly difficult because the typical equipment needed to perform the requisite analyses is expensive and cumbersome. Alternatively, researchers can use hand-held, relatively inexpensive, portable durometers that measure H on Shore scales. Shore-D durometers show a reliable ability to characterize H in harder-stiffer materials, and Shore-D measures in these materials can be reliably converted to E. Shore-A durometers-employed in past field studies of food properties-do not accurately characterize the properties of harder-stiffer materials, which are likely to be those materials exerting the greatest mechanical demands on primate masticatory morphology. We offer recommendations for Shore-D durometer usage in the field.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ajpa.21628DOI Listing

Publication Analysis

Top Keywords

elastic modulus
8
harder-stiffer materials
8
materials
5
technical note
4
note converting
4
converting durometer
4
durometer data
4
data elastic
4
modulus biological
4
biological materials
4

Similar Publications

In this study, the dispersion behavior of MoS₂ in ionic liquids (ILs) with varying alkyl chain lengths was the primary focus of investigation, followed by the design of a novel PAM/SMA/CMC/PDA@MoS hydrogel. By optimizing the concentrations of CMC and PDA@MoS, a bifunctional hydrogel with both sensing and catalytic functions was successfully developed. Mechanical tests revealed that the PAM/SMA/CMC/0.

View Article and Find Full Text PDF

This study aimed at assessing the mechanical properties and degradation of commercial bioactive materials. The bioactive materials (Activa Bioactive Restorative, Beautifil Flow Plus F00, F03, Predicta Bulk Bioactive) and composite resin Filtek Supreme Flow were submitted to flexural and diametral tensile strength tests (FS, DTS), modulus of elasticity (ME) evaluation, and analysis of aging in 70% ethanol and saliva on their hardness and sorption. The results for DTS ranged from 33.

View Article and Find Full Text PDF

A Force-Sensor-Less Approach for Rapid Young's Modulus Identification of Heterogeneous Soft Tissue.

J Biomech Eng

January 2025

State Key Laboratory of Fluid Power and Mechatronic Systems, Department of Mechanical Engineering, Zhejiang University, Hangzhou, 315000, China.

Due to individual differences, accurate identification of tissue elastic parameters is essential for biomechanical modeling in surgical guidance for hepatic venous injections. This paper aims to acquire the absolute Young's modulus of heterogeneous soft tissues during endoscopic surgery with 2D ultrasound images. First, we introduced a force-sensor-less approach that utilizes a pre-calibrated soft patch with a known Young's modulus and its ultrasound images to calculate the external forces exerted by the probe on the tissue.

View Article and Find Full Text PDF

The contribution of sex hormones to cardiovascular disease, including arterial stiffness, is established; however, the role of sex chromosome interaction with sex hormones, particularly in women, is lagging. Arterial structural stiffness depends on the intrinsic properties and transmural wall geometry that comprise a network of cells and extracellular matrix (ECM) proteins expressed in a sex-dependent manner. In this study, we used four-core genotype (FCG) mice to determine the relative contribution of sex hormones versus sex chromosomes or their interaction with arterial structural stiffness.

View Article and Find Full Text PDF

Exploration of the dynamics of otic capsule and intracochlear pressure: Numerical insights with experimental validation.

J Acoust Soc Am

January 2025

Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Zurich, University of Zurich, Zurich, Switzerland.

The otic capsule and surrounding temporal bone exhibit complex 3D motion influenced by frequency and location of the bone conduction stimulus. The resultant correlation with the intracochlear pressure is not sufficiently understood, thus is the focus of this study, both experimentally and numerically. Experiments were conducted on six temporal bones from three cadaver heads, with BC hearing aid stimulation applied at the mastoid and classical BAHA locations across 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!