Temperature measurement.

Biomed Tech (Berl)

RWTH Aachen, Germany.

Published: October 2011

For many decades the measurement of body core temperature has been ubiquitously established in medical and non-medical applications, e.g., in hospitals, occupational medicine, sports medicine, military and other settings. However, there are still numerous challenges, such as the precise definition of the body core temperature, establishing the clinical importance of the measured temperature and the lack of a reliable, non-invasive and fast measurement method for body core temperature. After an introduction to the topic, the medical aspects from a user point of view are presented, i.e., the needs for temperature measurements, as well as possible measurement sites and clinical specifications and needs are highlighted. Subsequently, technical methods are presented which are used for temperature measurement. The analysis of the technical methods is divided into two sections: the first deals with the standard methods, which are currently used and the second describes methods, which are currently under development. Although temperature measurement appears very easy and is very common in daily use, it has many constraints, which are considered later. The need for further research is deduced from the above-mentioned sections and is finally followed by the conclusions section.

Download full-text PDF

Source
http://dx.doi.org/10.1515/BMT.2011.108DOI Listing

Publication Analysis

Top Keywords

temperature measurement
12
body core
12
core temperature
12
temperature
8
presented temperature
8
technical methods
8
methods currently
8
measurement
5
measurement decades
4
decades measurement
4

Similar Publications

Malignant hyperthermia is a pharmacogenetic disorder that manifests clinically as a hypermetabolic crisis when a patient with a mutation in the ryanodine or dihydropyridine receptor genes is exposed to neuromuscular blocking agents. Depolarizing neuromuscular agents are known to cause malignant hyperthermia, but cases caused by nondepolarizing agents are rarely reported. We present a case consistent with malignant hyperthermia after receipt of cisatracurium, a nondepolarizing anesthetic agent.

View Article and Find Full Text PDF

The human skin maintains a comfortable and healthy somatosensory state by sensing different aspects of the thermal environment, including temperature value, heat source, energy level, and duration. However, state-of-the-art thermosensors only measure basic temperature values, not the full range of the thermosensation function of human skin. Here, we propose a heat source recognition () sensor of poly(butyl acrylate)-lithium bis(n-fluoroalkylsulfonyl)imide (PBA-Li:FSI;  = 1, 3, 5), which enables response to temperature, pressure, and proximity stimulus signals based on the relaxation behavior of the ionic gel and distinguished between different types of heat sources (i.

View Article and Find Full Text PDF

Water used in post-harvest handling and processing operations is an important risk factor for microbiological cross-contamination of fruits, vegetables and herbs (FVH). Industrial data indicated that the frozen FVH sector is characterised by operational cycles between 8 and 120 h, variable product volumes and no control of the temperature of process water. Intervention strategies were limited to the use of water disinfection treatments such as peroxyacetic acid and hydrogen peroxide.

View Article and Find Full Text PDF

Water used in post-harvest handling and processing operations is an important risk factor for microbiological cross-contamination of fruits, vegetables and herbs (FVH). Industrial data indicated that the fresh-cut FVH sector is characterised by process water at cooled temperature, operational cycles between 1 and 15 h, and product volumes between 700 and 3000 kg. Intervention strategies were based on water disinfection treatments mostly using chlorine-based disinfectants.

View Article and Find Full Text PDF

The patient's body temperature significantly fluctuates, affected by factors, including anesthesia. The ideal temperature monitoring method that is suitable for perioperative application is of great significance for identifying hypothermia and malignant hyperthermia early, as well as for guiding intraoperative temperature protection. This study aims to compare the cutaneous zero-heat-flux (ZHF) thermometer application in general anesthesia using the infrared tympanic measurement as a reference.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!