Objectives: To determine the visual 50:50% acceptability thresholds for lightness, chroma and hue for dental ceramics using CIEDE2000(K(L):K(C):K(H)) formula, and to evaluate the formula performance using different parametric factors.

Methods: A 30-observer panel evaluated three subsets of ceramic samples: lightness subset (|ΔL'/ΔE(00)| ≥ 0.9), chroma subset (|ΔC'/ΔE(00)| ≥ 0.9) and hue subset (|ΔH'/ΔE(00)| ≥ 0.9). A Takagi-Sugeno-Kang Fuzzy Approximation was used as fitting procedure, and the 50:50% acceptability thresholds were calculated. A t-test was used in statistical analysis of the thresholds values. The performance of the CIEDE2000(1:1:1) and CIEDE2000(2:1:1) colour difference formulas against visual results was tested using PF/3 performance factor.

Results: The 50:50% CIEDE2000 acceptability thresholds were ΔL' = 2.92 (95% CI 1.22-4.96; r(2) = 0.76), ΔC' = 2.52 (95% CI 1.31-4.19; r(2) = 0.71) and ΔH' = 1.90 (95% CI 1.63-2.15; r(2) = 0.88). The 50:50% acceptability threshold for colour difference (ΔE') for CIEDE2000(1:1:1) was 1.87, whilst corresponding value for CIEDE2000(2:1:1) was 1.78. The PF/3 values were 139.86 for CIEDE2000(1:1:1), and 132.31 for CIEDE2000(2:1:1).

Conclusions: There was a statistically significant difference amongst CIEDE2000 50:50% acceptability thresholds for lightness, chroma and hue differences for dental ceramics. The CIEDE2000(2:1:1) formula performed better than CIEDE2000(1:1:1).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jdent.2011.09.007DOI Listing

Publication Analysis

Top Keywords

acceptability thresholds
20
5050% acceptability
16
dental ceramics
12
thresholds lightness
12
lightness chroma
12
chroma hue
12
ciede2000 acceptability
8
hue differences
8
colour difference
8
acceptability
6

Similar Publications

Objective: This study aims to evaluate the clinical transfer accuracy of partially enclosed single hard vacuum-formed trays based on three-dimensional (3D) printed models for lingual bracket indirect bonding.

Materials And Methods: Thirty-two consecutive patients receiving lingual orthodontic treatment were enrolled. Digital models with ideal bracket positions were 3D-printed, followed by fabrication of partially enclosed single hard vacuum-formed trays.

View Article and Find Full Text PDF

Background: Breast implant surfaces are categorized as smooth or textured. Compared with smooth implants, textured surface implants have a higher risk of breast implant-associated anaplastic large cell lymphoma (BIA-ALCL) but may have a lower risk of capsular contracture (CC). This study aimed to quantify whether survey respondents would be willing to accept a higher risk of BIA-ALCL in exchange for the potential reported benefits of textured breast implants.

View Article and Find Full Text PDF

A dogma accepted in many ethical, religious, and legal frameworks is that the reasons behind conscientious objection (CO) in healthcare cannot be evaluated or judged by any institution because conscience is individual and autonomous. This paper shows that this background view is mistaken: the requirement to reveal and explain the reasons for conscientious objection in healthcare is ethically justified and legally desirable. Referring to real healthcare cases and legal regulations, this paper argues that these reasons should be evaluated either ex ante or ex post and defends novel conceptual claims that have not been analyzed in the debates on CO.

View Article and Find Full Text PDF

A new rhodamine based turn on florescent probe ()-3',6'-bis(ethylamino)-2-(((6-methoxy-2-oxo-1,2-dihydroquinolin-3-yl)methylene)amino)-2',7'-dimethylspiro[isoindoline-1,9'-xanthen]-3-one (RME) was efficiently synthesized through a simple condensation reaction of 2-amino-3',6'-bis(ethylamino)-2',7'-dimethylspiro[isoindoline-1,9'-xanthen]-3-one and 6-methoxy-2-oxo-1,2-dihydroquinoline-3-carbaldehyde. The receptor RME is highly non-fluorescent and when copper ions (Cu ions) are added in DMF/water (1 : 2, v/v) medium, the receptor RME exhibits a specific "turn-on" colorimetric and fluorometric response. Moreover, RME binding with Cu ions produced a remarkable color variation that was perceptible to the human eye, changing from colorless to pink.

View Article and Find Full Text PDF

Umbilical cord blood transplantation (CBT) is accepted as an effective treatment for acute myeloid leukemia (AML), and reduced-intensity conditioning (RIC), rather than myeloablative conditioning (MAC) regimens allowed elderly patients to be treated safely. However, appropriate intensities of conditioning regimens are still unclear, especially for middle-aged patients. To compare outcomes after RIC and MAC regimens, we analyzed AML patients aged 16 years or older in the Japanese registry database, who underwent single cord unit CBT between 2010-2019.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!