A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clinical wear of overdenture ball attachments after 1, 3 and 8 years. | LitMetric

Objectives: Implant-supported overdentures have become the treatment of choice in restoring complete edentulism, but the types of attachment to assure durable retention are a subject of debate. Ball attachments were reported as a simple treatment, but wear of components was responsible for a decrease in retention. The aim of this retrospective study was to measure the wear of the ball abutment or patrix after three different periods of clinical wear.

Material And Methods: Sixty-nine specimens of three groups of patrix that were in use for a mean of 12.3 months (group A), 39 months (group B) and 95.6 months (group C) were retrieved from 35 patients and measured on a coordinate measuring machine equipped with a touch trigger probe. Ten unused ball abutments were added as a control (group D). The patrix diameters and any deviation from circularity in different axes were measured.

Results: The diameters of groups A, B and C were significantly different from that of group D (control). No statistically significant differences were found between diameter and circularity variations between groups B and C. The maximal amount of diameter reduction was limited to approximately 30 μm, and 90% of diameter loss at the equator due to wear was reached in group B.

Conclusion: One, 3 and 8 years of clinical wear reduced significantly the diameters of the ball abutments tested, and the maximal amount of wear was reached after 3 years of clinical use.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1600-0501.2010.02102.xDOI Listing

Publication Analysis

Top Keywords

months group
12
clinical wear
8
ball attachments
8
ball abutments
8
maximal amount
8
wear reached
8
years clinical
8
group
6
ball
5
wear
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!