From a quality by design perspective, the aim of the present study was to demonstrate the applicability of a Bayesian statistical methodology to identify the Design Space (DS) of a spray-drying process. Following the ICH Q8 guideline, the DS is defined as the "multidimensional combination and interaction of input variables (e.g., materials attributes) and process parameters that have been demonstrated to provide assurance of quality." Thus, a predictive risk-based approach was set up in order to account for the uncertainties and correlations found in the process and in the derived critical quality attributes such as the yield, the moisture content, the inhalable fraction of powder, the compressibility index, and the Hausner ratio. This allowed quantifying the guarantees and the risks to observe whether the process shall run according to specifications. These specifications describe satisfactory quality outputs and were defined a priori given safety, efficiency, and economical reasons. Within the identified DS, validation of the optimal condition was effectuated. The optimized process was shown to perform as expected, providing a product for which the quality is built in by the design and controlled setup of the equipment, regarding identified critical process parameters: the inlet temperature, the feed rate, and the spray flow rate.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejpb.2011.09.014DOI Listing

Publication Analysis

Top Keywords

design space
8
spray-drying process
8
process parameters
8
process
7
design
4
space approach
4
approach optimization
4
optimization spray-drying
4
quality
4
process quality
4

Similar Publications

Effects of Noise and Public Setting on Blood Pressure Readings : A Randomized Crossover Trial.

Ann Intern Med

January 2025

Department of Epidemiology and Welch Center for Prevention, Epidemiology, and Clinical Research, Johns Hopkins Bloomberg School of Public Health, Baltimore; and Department of Pediatrics, Johns Hopkins University School of Medicine, Baltimore, Maryland (T.M.B.).

Background: Guidelines emphasize quiet settings for blood pressure (BP) measurement.

Objective: To determine the effect of noise and public environment on BP readings.

Design: Randomized crossover trial of adults in Baltimore, Maryland.

View Article and Find Full Text PDF

Monolithic Multiparameter Terahertz Nano/Microdetector Based on Plasmon Polariton Atomic Cavity.

Adv Mater

January 2025

State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-sen University, Guangzhou, 510275, China.

Terahertz (THz) signals are crucial for ultrawideband communication and high-resolution radar, demanding miniaturized detectors that can simultaneously measure multiple parameters such as intensity, frequency, polarization, and phase. Traditional detectors fail to meet these needs. To address this, we introduce a plasmon polariton atomic cavity (PPAC) detector based on monolayer graphene, offering a multifunctional, monolithic, and miniaturized solution.

View Article and Find Full Text PDF

Highly Optimized CNS Penetrant Inhibitors of EGFR Exon20 Insertion Mutations.

J Med Chem

January 2025

Pharmaron Beijing Co., Ltd., 6 Taihe Road, BDA, Beijing 100176, P. R. China.

Despite recent advances in the inhibition of EGFR (epidermal growth factor receptor), there remains a clinical need for new EGFR Exon20 insertion (Ex20Ins) inhibitors that spare EGFR WT. Herein, we report the discovery and optimization of two chemical series leading to ether and biaryl as potent, selective, and brain-penetrant inhibitors of Ex20Ins mutants. Building on our earlier discovery of alkyne which allowed access to CNS property space for an Ex20Ins inhibitor, we utilized structure-based design to move to lower lipophilicity and lower CL compounds while maintaining a WT selectivity margin.

View Article and Find Full Text PDF

Hierarchical Porous Aggregate-Enabled Chromatography-Inspired Single-Sensor E-Nose for Volatile Monitoring.

ACS Sens

January 2025

School of Chemistry and Molecular Engineering, In Situ Devices Research Center, Shanghai Key Laboratory for Urban Ecological Processes and Eco-Restoration, East China Normal University, Shanghai 200241, China.

Monitoring volatile organic compounds (VOCs) is crucial for ensuring safety and health. In this study, we introduce a strategy to engineer a chromatography-inspired single-sensor (CISS) e-nose tailored for VOC monitoring. This approach overcomes the limitations of traditional methodologies and conventional e-noses.

View Article and Find Full Text PDF

Supporting equitable access to kidney transplant in remote Western Australia using continuous quality improvement.

Int J Qual Health Care

January 2025

Kimberley Renal Services, PO Box 1377, Broome, Western Australia 6725, Australia.

Background: Despite an epidemic of end-stage kidney disease in the Australian Aboriginal and Torres Strait Islander population, disparities in access to kidney transplantation persist. The journey to a successful kidney transplant is long, with an initial suitability assessment required before waitlist-specific activities begin. In an Aboriginal Community Controlled renal service, we aimed to: (i) design and implement a continuous quality improvement (CQI) approach to transplant suitability assessment, (ii) provide transplant suitability assessments for all patients of the service, (iii) describe what temporary contraindications to kidney transplantation should be the focus of health service improvements, (iv) explore participant experiences with the suitability assessment process, and (v) use our findings to inform pre- and post-transplant model of care development within Kimberley Renal Services.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!