A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of HS270, a new histone deacetylase inhibitor, in rat plasma by LC-MS/MS--application to a preclinical pharmacokinetic study. | LitMetric

Determination of HS270, a new histone deacetylase inhibitor, in rat plasma by LC-MS/MS--application to a preclinical pharmacokinetic study.

J Chromatogr B Analyt Technol Biomed Life Sci

Laboratory of Drug Metabolism and Pharmacokinetics, School of Pharmaceutical Sciences, Sun Yat-sen University, Guangzhou, PR China.

Published: November 2011

AI Article Synopsis

  • A new and efficient LC-MS/MS method was developed to measure HS270, a histone deacetylase inhibitor, in rat plasma, using SAHA as an internal standard.
  • The method involves a quick liquid-liquid extraction and utilizes positive electro-spray ionization for analysis, achieving results in just 2.5 minutes.
  • This validated method demonstrated good recovery rates and accuracy, successfully applied in pharmacokinetic studies for various doses of HS270 in rats.

Article Abstract

A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method has been developed and fully validated to determine HS270, a new histone deacetylase (HDAC) inhibitor, in rat plasma using SAHA as the internal standard (IS). After a single step liquid-liquid extraction with acetoacetate, analytes were subjected to LC-MS/MS analysis using positive electro-spray ionization (ESI(+)) under selected reaction monitoring mode (SRM). The chromatographic separation was achieved on a Hypurity C(18) column (50 mm × 2.1 mm, i.d., 5 μm). The MS/MS detection was conducted by monitoring the fragmentation of m/z 392.3→100.1 for HS270, m/z 265.1→232.1 for IS. The method had a chromatographic running time of 2.5 min and linear calibration curves over the concentrations of 0.5-1000 ng/mL. The recovery of the method was 70.8-82.5% and the lower limit of quantification (LLOQ) was 0.5 ng/mL. The intra- and inter-batch precisions were less than 15% for all quality control samples at concentrations of 1.0, 100.0, and 750.0 ng/mL. The validated LC-MS/MS method has successfully applied to a HS270 pharmacokinetic study after oral doses of 25, 50, 100, 200 mg/kg, and i.v. dose of 5 mg/kg to rats.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2011.09.023DOI Listing

Publication Analysis

Top Keywords

hs270 histone
8
histone deacetylase
8
inhibitor rat
8
rat plasma
8
pharmacokinetic study
8
lc-ms/ms method
8
determination hs270
4
deacetylase inhibitor
4
plasma lc-ms/ms--application
4
lc-ms/ms--application preclinical
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!