Atrial pacing in the neonate is rarely done due to constraints of equipment, technical knowhow, and risk of complications. We describe a novel method of atrial pacing in the new born using equipment readily available in any intensive care unit. Atrial pacing can be achieved using an adult bipolar pacing wire directly introduced through the umbilical venous route. We have used this method in 5 neonates, and achieved atrial capture in 4 patients. Temporary atrial pacing is a therapeutic option in a few neonatal arrhythmias, such as atrial flutter, a few types of re-entrant tachycardias, such as accessory pathway mediated tachycardia and junctional reciprocating tachycardia, and has a limited role in cardiopulmonary resuscitation where sinoatrial node dysfunction is suspected.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3180977 | PMC |
http://dx.doi.org/10.4103/0974-2069.84661 | DOI Listing |
Pacing Clin Electrophysiol
December 2024
Division of Cardiology, Department of Medicine, Weill Cornell Medicine, New York Presbyterian Hospital, New York, USA.
Leadless pacing technology now includesdedicated atrial helix-fixation leadless pacemakers (LPs), expanding theapplication of leadless devices for patients with sinus node dysfunction andatrioventricular block during sinus rhythm. This first reportedcase-series of atrial LPs describes and discusses the potential use-casescenarios of recently approved helix-fixation atrial LPs. The article highlights important concepts regarding their use, including implantationtechniques, programming, battery conservation, and the low rate of progressionof AV block in patients implanted with AAI(R) pacemakers.
View Article and Find Full Text PDFPacing Clin Electrophysiol
December 2024
Department of Cardiology, International University of Health and Welfare Hospital, Tochigi, Japan.
Background: Cryoballoon ablation has been widely performed in patients with paroxysmal atrial fibrillation (AF). In some challenging pulmonary veins (PVs), the procedure requires additional touch-up applications against the residual conduction gaps. It implies that there could exist difficult sites to cover with standard cryoballoon applications (CBAs), resulting in resistant conduction gaps (RCGs).
View Article and Find Full Text PDFBMC Cardiovasc Disord
December 2024
Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian, China.
Background: Delayed lead perforation is a rare complication of cardiac implantable electronic device (CIED). Clinical presentations range from completely asymptomatic to pericardial tamponade. Surgical lead extraction is recommended and transvenous lead extraction (TLE) with surgical backup is an alternative method.
View Article and Find Full Text PDFJ Cardiovasc Dev Dis
December 2024
Institute of Cardiovascular Sciences, University of Birmingham, Birmingham B15 2TT, UK.
Background Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a rare genetic disorder associated with an elevated risk of life-threatening arrhythmias and progressive ventricular impairment. Risk stratification is essential to prevent major adverse cardiac events (MACE). Our study aimed to investigate the incremental value of strain measured by two-dimensional speckle-tracking echocardiography in predicting MACE in ARVC patients compared to conventional echocardiographic parameters.
View Article and Find Full Text PDFDiseases
December 2024
5th Department of Internal Medicine, Faculty of Medicine, "Iuliu Hațieganu" University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania.
Recently published data suggested significantly lower pacing-induced cardiomyopathy (PICM) incidence with conduction system pacing (CSP). Because most data evaluated only the impact on the left ventricle, this study aimed to assess changes in echocardiographic parameters of morphology and function for all heart chambers in patients with baseline preserved and mid-range LVEF over a medium-term follow-up period after CSP. A total of 128 consecutive patients with LVEF > 40% and successful CSP for bradyarrhythmic indication were prospectively enrolled.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!