The effects of non-cardioid directivity on incidence angle estimation using the polar energy time curve.

J Acoust Soc Am

Acoustics Research Group, Department of Physics and Astronomy, Brigham Young University, N283 Eyring Science Center, Provo, Utah 84602, USA.

Published: October 2011

Assessment of desirable reflections and control of undesirable reflections in rooms are best accomplished if the reflecting surfaces are properly localized. Several measurement techniques exist to identify the incident direction of reflected sound, including the useful polar energy time curve (Polar ETC), which requires six cardioid impulse response measurements along the Cartesian axes. The purpose of this investigation is to quantify the incidence angle estimation error introduced into the Polar ETC by non-cardioid microphone directivities. The results demonstrate that errors may be minimized with a cardioid-family microphone possessing a certain range of directivities and by maximizing the measurement signal-to-noise ratio.

Download full-text PDF

Source
http://dx.doi.org/10.1121/1.3635298DOI Listing

Publication Analysis

Top Keywords

incidence angle
8
angle estimation
8
polar energy
8
energy time
8
time curve
8
effects non-cardioid
4
non-cardioid directivity
4
directivity incidence
4
polar
4
estimation polar
4

Similar Publications

Correlations between spinopelvic parameters and health-related quality of life in degenerative lumbar scoliosis patients before and after long -level fusion surgery.

BMC Musculoskelet Disord

January 2025

Department of Orthopedics, Peking University Third Hospital, No. 49. North Garden Street, Hai Dian District, Beijing, 100191, People's Republic of China.

Background: For degenerative lumbar scoliosis (DLS), prior studies mainly focused on the preoperative relationship between spinopelvic parameters and health-related quality of life (HRQoL), lacking an exhaustive evaluation of the postoperative situation. Therefore, the postoperative parameters most closely bonded with clinical outcomes has not yet been well-defined in DLS patients. The objective of this study was to comprehensively assess the correlation between radiographic parameters and HRQoL before and after surgery, and to identified the most valuable spinopelvic parameters for postoperative curative effect.

View Article and Find Full Text PDF

This research proposes an all-metal metamaterial-based absorber with a novel geometry capable of refractive index sensing in the terahertz (THz) range. The structure consists of four concentric diamond-shaped gold resonators on the top of a gold metal plate; the resonators increase in height by 2 µm moving from the outer to the inner resonators, making the design distinctive. This novel configuration has played a very significant role in achieving multiple ultra-narrow resonant absorption peaks that produce very high sensitivity when employed as a refractive index sensor.

View Article and Find Full Text PDF

This research presents an innovative polarization-insensitive metasurface (MS) harvester designed for energy harvesting applications at 5 GHz, capable of operating efficiently over wide reception angles. The proposed MS features a novel wheel-shaped resonator array whose symmetrical structure ensures insensitivity to the polarization of incident electromagnetic (EM) waves, enabling efficient energy absorption and minimizing reflections. Unlike conventional designs, the metasurface achieves near-unity harvesting efficiency, exceeds 94% under normal incidence, and maintains superior performance across various incident angles for TE and TM polarizations.

View Article and Find Full Text PDF

A Review on Face Mask Recognition.

Sensors (Basel)

January 2025

School of Information and Communications Engineering, Xi'an Jiaotong University, Xi'an 710049, China.

This review offers a comprehensive and in-depth analysis of face mask detection and recognition technologies, emphasizing their critical role in both public health and technological advancements. Existing detection methods are systematically categorized into three primary classes: feaRture-extraction-and-classification-based approaches, object-detection-models-based methods and multi-sensor-fusion-based methods. Through a detailed comparison, their respective workflows, strengths, limitations, and applicability across different contexts are examined.

View Article and Find Full Text PDF

: The aim of this study was to investigate the incidence of vertebral refractures following percutaneous kyphoplasty (PKP) and to explore risk factors for augmented vertebral refractures, thereby assisting spinal surgeons in clinical practice. : We analyzed the records of 495 patients with single-segment osteoporotic vertebral compression fractures (OVCFs) who were treated with single-entry PKP at our institution from March 2016 to August 2022. Univariate analysis, binary logistic regression, and ROC curve analysis were performed to determine potential risk factors, independent risk factors, and discrimination ability.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!