Ultrasmall superparamagnetic iron oxide nanoparticles (USPIOs) have attracted attention because of their current and potential usefulness as contrast agents for magnetic resonance imaging (MRI) and nuclear magnetic resonance (NMR). USPIOs are usually used for their significant capacity to produce predominant proton relaxation effects, which result in signal reduction. However, most previous studies that utilized USPIOs have been focused on the relaxation behavior at commonly used magnetic fields of clinical MRI systems (typically 1-3 T). In this paper, magnetic relaxation processes of protons in water surrounding the USPIOs are studied at ultralow (≤10 mT) and ultrahigh magnetic fields (14.1 T). USPIOs used in our experiments were synthesized with a core size of 6 nm, and transferred from organic to water by ligand exchange. The proton spin-lattice relaxation time (T(1)) and spin-spin relaxation time (T(2)) were investigated at ultralow (212 μT for T(2) and 10 mT for T(1)) and at 14.1 T with different iron concentrations. At all of the fields, there is a linear relationship between the inverse of relaxation times and the iron concentration. The spin-spin relaxivity (r(2)) at 14.1 T is much larger than that value of the ultralow field. At ultralow field, however, the spin-lattice relaxivity (r(1)) is larger than the r(1) at ultrahigh field. The results provide a perspective on potential in vivo and in vitro applications of USPIOs in ultralow and ultrahigh field NMR and MRI.

Download full-text PDF

Source
http://dx.doi.org/10.1021/jp2066138DOI Listing

Publication Analysis

Top Keywords

magnetic fields
12
relaxation behavior
8
ultrasmall superparamagnetic
8
superparamagnetic iron
8
iron oxide
8
oxide nanoparticles
8
ultralow ultrahigh
8
ultrahigh magnetic
8
magnetic resonance
8
relaxation time
8

Similar Publications

[Clinical characteristics and prognosis of type 1 infratentorial superficial siderosis].

Zhonghua Yi Xue Za Zhi

February 2025

Department of Neurology, Huashan Hospital, Fudan University, Shanghai 200040, China.

A total of 7 patients with type 1 infratentorial superficial siderosis(iSS-1)in Memory Clinic at Huashan Hospital, Fudan University from March 2019 to March 2023 were respectively collected to analyze the clinical characteristics and treatment, and followed up for 12 months. There were 7 patients, 2 males and 5 females, aged 56 (49-60) years. The 4 patients who underwent cognitive assessment had varying degree of cognitive impairment, with 2 patients exhibiting severe executive function impairment.

View Article and Find Full Text PDF

Optically pumped magnetometers (OPMs) functioning in the spin-exchange relaxation-free (SERF) regime have emerged as attractive options for measuring weak magnetic fields, owing to their portability and remarkable sensitivity. The operation of SERF-OPM critically relies on the ambient magnetic field; thus, a magnetic field compensation device is commonly employed to mitigate the ambient magnetic field to near zero. Nonetheless, the bias of the OPM may influence the compensation impact, a subject that remains unexamined.

View Article and Find Full Text PDF

The electronic structure characteristics of bilayer graphyne, bilayer graphdiyne, and bilayer graphtriyne were systematically studied using molecular orbital (MO) analysis, density of states (DOS), and interaction region indicator (IRI) methods. The delocalization characteristics of the out-of-plane and in-plane π electrons (i.e.

View Article and Find Full Text PDF

The aim of this study was to evaluate the effectiveness of Fascial Manipulation in patients with disc herniations of the lumbar spine confirmed by magnetic resonance imaging. This study included 69 patients with intervertebral disc damage of the lumbar spine, as confirmed by magnetic resonance imaging. Patients were divided into two groups: a study group and a control group.

View Article and Find Full Text PDF

Equation for Calculation of Critical Current Density Using the Bean's Model with Self-Consistent Magnetic Units to Prevent Unit Conversion Errors.

Materials (Basel)

January 2025

Laboratory for Heteroepitaxial Growth of Functional Materials & Devices, Department of Chemical & Biological Engineering, State University of New York (SUNY) at Buffalo, Buffalo, NY 14260, USA.

This study analyzes the calculation of the critical current density by means of Bean's critical state model, using the equation formulated by Gyorgy et al. and other similar equations derived from it reported in the literature. While estimations of using Bean's model are widely performed, improper use of different equations with different magnetic units and pre-factors leads to confusion and to significant errors in the reported values of .

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!