A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Validation of a protocol to evaluate maximal expiratory pressure using a pressure transducer and a signal conditioner. | LitMetric

Validation of a protocol to evaluate maximal expiratory pressure using a pressure transducer and a signal conditioner.

An Acad Bras Cienc

Programa de Pós-Gradua..o em Ciências da Saúde da UFG, Laboratório de Bioengenharia e Biomecanica/LaBioEng, Universidade Federal de Goiás, Campus Samambaia, Goiania, GO, Brasil.

Published: September 2011

AI Article Synopsis

  • The study focuses on evaluating the Maximal Expiratory Pressure (MEP) in young adults aged 20 to 25 and validating a protocol using a pressure transducer.
  • Participants performed six respiratory maneuvers to measure their MEP, aiming to assess the reliability of the device compared to a digital manometer.
  • Results indicated no significant differences in MEP values from existing literature, confirming that the pressure transducer is a reliable tool for measuring respiratory muscle strength.

Article Abstract

The respiratory muscles can present fatigue and even chronic inability to generate force. So, reliable devices are necessary to their evaluation. The aim of this study is to evaluate the MEP (Maximal Expiratory Pressure) values of individuals between 20 and 25 years old and to validate a protocol using a pressure transducer and a signal conditioner comparing it with the digital manometer. We evaluated the MEP of 10 participants. They remained seated and made six respiratory maneuvers from Total Lung Capacity (TLC) to Residual Volume (RV). The results in the study showed no statistically significant differences when compared to values reported in the literature, and that the pressure transducer provides reliable values for MEP.

Download full-text PDF

Source
http://dx.doi.org/10.1590/s0001-37652011005000021DOI Listing

Publication Analysis

Top Keywords

pressure transducer
12
maximal expiratory
8
expiratory pressure
8
transducer signal
8
signal conditioner
8
pressure
5
validation protocol
4
protocol evaluate
4
evaluate maximal
4
pressure pressure
4