Recent advances in assay technology have led to major improvements in how HIV-1 neutralizing antibodies are measured. A luciferase reporter gene assay performed in TZM-bl (JC53bl-13) cells has been optimized and validated. Because this assay has been adopted by multiple laboratories worldwide, an external proficiency testing program was developed to ensure data equivalency across laboratories performing this neutralizing antibody assay for HIV/AIDS vaccine clinical trials. The program was optimized by conducting three independent rounds of testing, with an increased level of stringency from the first to third round. Results from the participating domestic and international laboratories improved each round as factors that contributed to inter-assay variability were identified and minimized. Key contributors to increased agreement were experience among laboratories and standardization of reagents. A statistical qualification rule was developed using a simulation procedure based on the three optimization rounds of testing, where a laboratory qualifies if at least 25 of the 30 ID50 values lie within the acceptance ranges. This ensures no more than a 20% risk that a participating laboratory fails to qualify when it should, as defined by the simulation procedure. Five experienced reference laboratories were identified and tested a series of standardized reagents to derive the acceptance ranges for pass-fail criteria. This Standardized Proficiency Testing Program is the first available for the evaluation and documentation of assay equivalency for laboratories performing HIV-1 neutralizing antibody assays and may provide guidance for the development of future proficiency testing programs for other assay platforms.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3332116PMC
http://dx.doi.org/10.1016/j.jim.2011.09.007DOI Listing

Publication Analysis

Top Keywords

proficiency testing
16
testing program
12
neutralizing antibody
12
antibody assay
8
hiv-1 neutralizing
8
equivalency laboratories
8
laboratories performing
8
rounds testing
8
simulation procedure
8
acceptance ranges
8

Similar Publications

Positive self-perception, physical activity and fundamental movement skill (FMS) proficiency are important aspects of a child's healthy development. The objective of this research was twofold: first, to explore associations between FMS, muscular fitness, self-perception and physical activity in school children; and second, to identify key predictors of FMS proficiency, athletic self-perception, physical activity levels in these participants and the differences between biological sexes. Primary school-aged children (n = 104; 53.

View Article and Find Full Text PDF

Objective: Clinicians face challenges in managing the growing population of patients with limited English proficiency (LEP) and hearing loss (HL) in the United States. This study seeks to investigate provider perspectives on evaluating, counseling, and treating HL in LEP patients.

Study Design: Prospective descriptive study.

View Article and Find Full Text PDF

Background: Developing proficiency in ultrasound-guided nerve block (UGNB) demands an intricate understanding of cross-sectional anatomy as well as spatial reasoning, which is a big challenge for beginners. The aim of this pilot study was to evaluate the feasibility of virtual reality (VR)-facilitated anatomy education in the first performance of ultrasound-guided interscalene brachial plexus blockade among novice anesthesiologists. We carried out pilot testing of this hypothesis using a prospective, single blind, randomized controlled trial.

View Article and Find Full Text PDF

Interlaboratory variability of HER2 fluorescence in situ hybridization testing in breast cancer: results of a multicenter proficiency-testing ring study in China.

Diagn Pathol

December 2024

National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology, No.1 Da Hua Road, Dongdan, Beijing, 100730, People's Republic of China.

Background: Accurate detection of human epidermal growth factor receptor 2 (HER2) gene amplification via fluorescence in situ hybridization (FISH) is necessary to determine HER2 status. Although many attempts have been made to increase the consistency of the results, the actual situation still needs to be determined. To investigate the latest interlaboratory variability of HER2 FISH testing for breast cancer, a multicenter proficiency-testing ring study was conducted in China.

View Article and Find Full Text PDF

An Improved GC-MS/MS Method for a Fast Multidrug Analysis in Hair.

Drug Test Anal

December 2024

Analytical Toxicology Laboratory, Analytical Toxicology Division, Health Sciences Authority, Singapore.

This study presents the development and validation of a drug testing method in hair, employing a semi-automated sample preparation procedure and gas chromatography-tandem mass spectrometry (GC-MS/MS) for simultaneous multidrug analysis in hair. The method aims to detect and quantify multiple drugs in hair, including amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, 3,4-methylenedioxymethamphetamine, ketamine, norketamine, cocaine, benzoylecgonine, morphine, codeine and 6-monoacetylmorphine, using a comprehensive procedure involving decontamination, pulverization, clean-up using supported-liquid extraction (SLE) and a two-step derivatization process. The method validation included specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, carryover, robustness and stability.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!