A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Premature antibodies with rapid reaction kinetics and their characterization for diagnostic applications. | LitMetric

Premature antibodies with rapid reaction kinetics and their characterization for diagnostic applications.

Anal Biochem

Department of Bio-Microsystem Technology, Korea University, Sungbuk-gu, Seoul 136-701, Republic of Korea.

Published: January 2012

In this study, rapidly reversible antibodies were produced and the binding kinetics, stability, and utility as an analytical binder were evaluated. The number of times the animals were immunized with the antigen (myoglobin as marker for acute myocardial infarction [AMI]) was limited to two, increasing the chances of producing premature antibodies that rapidly reacted with the binding partner in both association and dissociation. The rate constants were higher than 1×10(6)M(-1)s(-1) and 1×10(-3)s(-1), respectively, and the affinity exceeded 10(8)M(-1). They responded to an abrupt environmental change (acidic pH in this study) where the reaction kinetics was changed to slow binding, particularly for dissociation, resulting in a 10-fold increase in affinity. The binding characteristic before and after the transition were stable at 37°C for longer than 1 month, suggesting that the rapidly reversible antibody was the intermediate of the slow binder. The rapid kinetic antibody was used as the primary binder in the conventional competitive immunoassay, which displayed a lower sensitivity than the transformed antibody due to its lower affinity. We further demonstrated that, on combination with a microfluidic label-free sensor, the reaction could be continuously monitored in serum medium by recycling the same antibody without employing the regeneration step.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ab.2011.09.006DOI Listing

Publication Analysis

Top Keywords

premature antibodies
8
reaction kinetics
8
rapidly reversible
8
antibodies rapid
4
rapid reaction
4
kinetics characterization
4
characterization diagnostic
4
diagnostic applications
4
applications study
4
study rapidly
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!