The measurement of absorbed dose to water in a solid-phantom may require a conversion factor because it may not be radiologically equivalent to water. One phantom developed for the use of dosimetry is a solid water, RW3 white-polystyrene material by IBA. This has a lower mass-energy absorption coefficient than water due to high bremsstrahlung yield, which affects the accuracy of absolute dosimetry measurements. In this paper, we demonstrate the calculation of mass-energy absorption coefficient ratios, relative to water, from measurements in plastic water and RW3 with an Elekta Synergy linear accelerator (6 and 10 MV photon beams) as well as Monte Carlo modeling in BEAMnrc and DOSXYZnrc. From this, the solid-phantom-to-water correction factor was determined for plastic water and RW3.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s13246-011-0102-4 | DOI Listing |
Radiat Prot Dosimetry
November 2024
Nuclear and Ionizing Radiation Metrology Section, Office of Atoms for Peace, Bangkok 10900, Thailand.
Interventional radiology (IR) provides significant advancements in diagnostic and therapeutic procedures, yet concerns persist regarding radiological risks such as erythema, burns, and epilation. Direct dose measurements observed difficulties regarding the perturbation of the detector probe in X-ray images during fluoroscopy-guided procedures, high-cost expenses, and non-compliant patients. This study aims to develop a statistical-based model for estimating entrance skin dose (ESD) in body IR procedures using patient radiation-dose recording data.
View Article and Find Full Text PDFBiomed Phys Eng Express
September 2024
Department of Medical Imaging and Radiological Sciences, Tzu-Chi University, Hualien, Taiwan.
Biomed Phys Eng Express
May 2024
Medical Physics Service, Hospital Universitario Puerta del Mar, Avda. Ana de Viya, No 21. 11009, Cádiz, Spain.
. New applications of 3D printing have recently appeared in the fields of radiotherapy and radiology, but the knowledge of many radiological characteristics of the compounds involved is still limited. Therefore, studies are needed to improve our understanding about the transport and interaction of ionizing radiation in these materials.
View Article and Find Full Text PDFAppl Radiat Isot
April 2024
Hercules Laboratory, University of Evora, Portugal.
Total, whole-atom, individual and integrated Compton scattering cross sections and Compton energy absorption scattering cross sections are evaluated for light elements, such as, H, C, N, O, P, and Ca, with relativistic impulse approximation methods. Most of the phantom materials composed of these elements, which are the basic constituents of biological soft-tissue and attenuation through them, provides potential source of information. Compton scattering cross-sections for few biological materials, such as, HO, CH, CH, CHO, CHNO, CHO, CHO, [Ca(PO)]Ca (OH) of medical interest, have been evaluated with the use of double differential scattering cross-section based on impulse approximation.
View Article and Find Full Text PDFPhys Med Biol
August 2023
VSL-National Metrology Institute, Delft, NL, The Netherlands.
. Despite the number of treatments performed with electronic brachytherapy (eBT) there is no uniform methodology for reference dosimetry for international traceability to primary dosimetry standards in different eBT systems. The objective of this study is to propose a formalism for traceability reference dosimetry in superficial eBT, that is easy to apply in the clinic.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!