Determination of RW3-to-water mass-energy absorption coefficient ratio for absolute dosimetry.

Australas Phys Eng Sci Med

Radiation Oncology, Princess Alexandra Hospital, Woolloongabba, Brisbane, QLD 4120, Australia.

Published: December 2011

The measurement of absorbed dose to water in a solid-phantom may require a conversion factor because it may not be radiologically equivalent to water. One phantom developed for the use of dosimetry is a solid water, RW3 white-polystyrene material by IBA. This has a lower mass-energy absorption coefficient than water due to high bremsstrahlung yield, which affects the accuracy of absolute dosimetry measurements. In this paper, we demonstrate the calculation of mass-energy absorption coefficient ratios, relative to water, from measurements in plastic water and RW3 with an Elekta Synergy linear accelerator (6 and 10 MV photon beams) as well as Monte Carlo modeling in BEAMnrc and DOSXYZnrc. From this, the solid-phantom-to-water correction factor was determined for plastic water and RW3.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s13246-011-0102-4DOI Listing

Publication Analysis

Top Keywords

mass-energy absorption
12
absorption coefficient
12
water rw3
12
absolute dosimetry
8
plastic water
8
water
7
determination rw3-to-water
4
rw3-to-water mass-energy
4
coefficient ratio
4
ratio absolute
4

Similar Publications

Statistical-based modeling strategy for entrance skin dose estimation in patient undergoing body interventional radiology.

Radiat Prot Dosimetry

November 2024

Nuclear and Ionizing Radiation Metrology Section, Office of Atoms for Peace, Bangkok 10900, Thailand.

Interventional radiology (IR) provides significant advancements in diagnostic and therapeutic procedures, yet concerns persist regarding radiological risks such as erythema, burns, and epilation. Direct dose measurements observed difficulties regarding the perturbation of the detector probe in X-ray images during fluoroscopy-guided procedures, high-cost expenses, and non-compliant patients. This study aims to develop a statistical-based model for estimating entrance skin dose (ESD) in body IR procedures using patient radiation-dose recording data.

View Article and Find Full Text PDF

Comparison of Monte Carlo tally techniques for dosimetry in a transmission-type x-ray tube.

Biomed Phys Eng Express

September 2024

Department of Medical Imaging and Radiological Sciences, Tzu-Chi University, Hualien, Taiwan.

Article Synopsis
  • This study compared the accuracy and time efficiency of different tally methods using MCNP6 for a novel x-ray tube designed for Auger electron yield with materials like iodine.
  • Key assessments included photon spectrum analysis, dose measurements in both air and water, and mass-energy absorption coefficients, showing slight variations in mean energy between different media.
  • The FMESH tally method demonstrated better efficiency over the F6 tally for dose calculations, which could enhance treatment planning systems by quickly generating necessary data for diverse physical conditions.
View Article and Find Full Text PDF

Thermoplastic polymers as water substitutes.

Biomed Phys Eng Express

May 2024

Medical Physics Service, Hospital Universitario Puerta del Mar, Avda. Ana de Viya, No 21. 11009, Cádiz, Spain.

. New applications of 3D printing have recently appeared in the fields of radiotherapy and radiology, but the knowledge of many radiological characteristics of the compounds involved is still limited. Therefore, studies are needed to improve our understanding about the transport and interaction of ionizing radiation in these materials.

View Article and Find Full Text PDF

Total, whole-atom, individual and integrated Compton scattering cross sections and Compton energy absorption scattering cross sections are evaluated for light elements, such as, H, C, N, O, P, and Ca, with relativistic impulse approximation methods. Most of the phantom materials composed of these elements, which are the basic constituents of biological soft-tissue and attenuation through them, provides potential source of information. Compton scattering cross-sections for few biological materials, such as, HO, CH, CH, CHO, CHNO, CHO, CHO, [Ca(PO)]Ca (OH) of medical interest, have been evaluated with the use of double differential scattering cross-section based on impulse approximation.

View Article and Find Full Text PDF

. Despite the number of treatments performed with electronic brachytherapy (eBT) there is no uniform methodology for reference dosimetry for international traceability to primary dosimetry standards in different eBT systems. The objective of this study is to propose a formalism for traceability reference dosimetry in superficial eBT, that is easy to apply in the clinic.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!